OMRON ZX-E Sensors
last update: September 24, 2012
Small Sensor Heads are perfect for detecting the height of small objects and for applications where multiple Sensor Heads are used.
Sensors with stainless steel Protective Spiral Tubes are also available.
The temperature characteristic ranks at the top in the industry at 0.1% FS/°C for heat-resistive sensors, and it ranges up to 200°C for flat sensors.
The Amplifier Unit can be used as is when replacing damaged Sensor Heads or changing the Sensor Head for different detection distances.
The distance between the Amplifier Units the Sensor Heads can be extended to 3 m, 6 m, or 10 m using a ZX-XC[]A Cable (sold separately).
Adjustments using the adjustment knob are no longer required to adjust linearity. Linearity adjustment is completed simply by teaching at 0%, 50%, and 100% of the measurement distance, greatly reducing setting time.
Linearity is worse for non-ferrous than ferrous sensing objects. A material selection function has been developed to improve linearity with stainless steel and aluminum sensing objects.
Multiple Sensors may be used in confined spaces for level difference measurements or multiple-point measurements. Mutual interference between up to 5 Sensors can be prevented simply by connecting Calculating Units to eliminate the need for timing signals on the user side.
The calculation results from two Sensors can be displayed on the Amplifier for one Sensor simply by placing a Calculating Unit between the Amplifier Units. The required parameters need to be input only into one Amplifier Unit.
last update: September 24, 2012
If you have just landed here, this product OMRON ZX-E Sensors,Sensors is offered online by Tianin FLD Technical Co.,Ltd. This is an online store providing Sensors at wholesale prices for consumers. You can call us or send enquiry, we would give you the prices, packing,deliverty and more detailed information on the ZX-E We cooperate with DHL,TNT,FEDEX,UPS,EMS,etc.They guarantee to meet your needs in terms of time and money,even if you need your OMRON ZX-ESensors tomorrow morning (aka overnight or next day air) on your desk, 2, 3 days or more.Note to international customers, YES, we ship worldwide.
G7Z Power Relays/Features
CS Series Programmable Controllers/Features
NX7 NX7 Overview/Features
CJ1W-PRT21 PROFIBUS-DP slave unit/Features
3G8F7-DRM21-E DeviceNet Board (PCI Board)/Features
last update: November 09, 2016
| Shape | Dimensions | Sensing distance | Resolution *1 | Model |
|---|---|---|---|---|
| Cylindrical | 3 dia. x 18 mm | 0.5 mm | 1 μm | ZX-EDR5T |
| 5.4 dia. x 18 mm | 1 mm | ZX-ED01T *2 | ||
| 8 dia. x 22 mm | 2 mm | ZX-ED02T *2 | ||
| Screw-shaped | M10 x 22 mm | ZX-EM02T *2 | ||
| M18 x 46.3 mm | 7 mm | ZX-EM07MT *2 | ||
| Flat | 30 x 14 x 4.8 mm | 4 mm | ZX-EV04T *2 *3 | |
| Heat-resistant, cylindrical | M12 x 22 mm | 2 mm | ZX-EM02HT *4 |
*1:For an average count of 4,096.
*2:Models with Protective Spiral Tubes are also available. Add a suffix of “-S” to the above model numbers when ordering.
(Example: ZX-ED01T-S)
As for ZX-EM07MT, please mention ZX-EM07M-S when ordering.
For detailed dimensions of the Protective Spiral Tube, refer to the information on the E39-F32A on the OMRON website.
*3: Be sure to use ZX-EDA Amplifier Unit version 1,200 or later with the ZX-EV04T.
*4: Be sure to use ZX-EDA Amplifier Unit version 1,300 or later with the ZX-EM02HT.
| Appearance | Power supply | Output type | Model |
|---|---|---|---|
![]() | DC | NPN | ZX-EDA11 2M |
| PNP | ZX-EDA41 2M |
Note: Compatible connection with the Sensor Head.
| Appearance | Model |
|---|---|
![]() | ZX-CAL2 |
A ZX-XBE1 is provided with the Sensor. Order an Amplifier Mounting Bracket separately if required.
| Appearance | Model | Remarks |
|---|---|---|
![]() | ZX-XBE1 | Attached to each Sensor Head |
![]() | ZX-XBE2 | For DIN track mounting |
| Appearance | Name | Model |
|---|---|---|
![]() | Communications Interface Unit (RS-232C) | ZX-SF11 |
![]() | Smart Monitor (Logging Software + Function Setting Software) | ZX-SW11EV3 *1 |
| Appearance | Name | Model |
|---|---|---|
![]() | Communications Interface Unit (RS-232C) + Smart Monitor Basic *2 (Function Setting Software) | ZX-SFW11EV3 *1 |
*1. The ZX-SFW11EV3 or ZX-SW11EV3 is required to use the Smart Monitor with the ZX-LDA11-N/41-N. Earlier versions cannot be used.
*2. The Smart Monitor Basic does not have a logging function.
Other than the logging function, the Smart Monitor Basic supports the same functions as the Smart Monitor.
| Cable length | Model | Quantity |
|---|---|---|
| 1 m | ZX-XC1A | 1 |
| 4 m | ZX-XC4A | |
| 8 m | ZX-XC8A |
* Robot cable models are also available. The model numbers are ZX-XC[]R.
| Appearance | Model |
|---|---|
![]() | ZX-SB11 |
last update: November 09, 2016
last update: April 25, 2013
last update: April 25, 2013
| Catalog Name | Catalog Number [size] | Last Update | |
|---|---|---|---|
| | E331-E1 [807KB] | Nov 09, 201620161109 | ZX-E Series Data Sheet |
last update: April 25, 2013
| Model | ZX-EDR5T | ZX- ED01T | ZX-ED02T/ EM02T | ZX- EM07MT | ZX-EV04T | ZX-EM02HT | ||
|---|---|---|---|---|---|---|---|---|
| Measurement range | 0 to 0.5 mm | 0 to 1 mm | 0 to 2 mm | 0 to 7 mm | 0 to 4 mm | 0 to 2 mm | ||
| Sensing object | Magnetic metals (Measurement ranges and linearities are different for non-magnetic metals. Refer to Engineering Data on See Engineering Data (Typical).) | |||||||
| Standard reference object | 18 × 18 × 3 mm | 30 × 30 × 3 mm | 60 × 60 × 3 mm | 45 × 45 × 3 mm | ||||
| Material: ferrous (S50C) | ||||||||
| Resolution *1 | 1 μm | |||||||
| Linearity *2 | ± 0.5% F.S. | ± 1.0% F.S. *5 | ||||||
| Linear output range | Same as measurement range. | |||||||
| Temperature characteristic *3 (including Amplifier Unit) | 0.15 % F.S./°C | 0.07% F.S./°C | 0.1% F.S./°C | |||||
| Ambient temper- ature | Operating *4 | 0 to 50°C (with no icing or con- densation) | -10 to 60°C (with no icing or condensation) | -10 to 200°C (with no icing or condensa- tion) | ||||
| Storage *4 | -20 to 70°C (with no icing or condensation) | |||||||
| Ambient humidity | Operating and storage: 35% to 85% (with no condensation) | |||||||
| Insulation resistance | 50 MΩ min. (at 500 DC) | |||||||
| Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min between charged parts and case | |||||||
| Vibration resistance (destruction) | 10 to 55 Hz with 1.5-mm double amplitude for 2 h each in X, Y, and Z directions | |||||||
| Shock resistance (destruction) | 500 m/s2, 3 times each in X, Y, and Z directions | |||||||
| Degree of protection (Sensor Head) | IEC60529, IP65 | IEC60529, IP67 | IEC60529, IP60 *6 | |||||
| Connection method | Connector relay (standard cable length: 2 m) | |||||||
| Weight (packed state) | Approx. 120 g | Approx. 140 g | Approx. 160 g | Approx. 130 g | Approx. 160 g | |||
| Materials | Sensor Head | Case | Brass | Stainless steel | Brass | Zinc (nickel- plated) | Brass | |
| Sensing surface | Heat-resistant ABS | PEEK | ||||||
| Tightening nut | --- | Brass (nickel-plated) (except ZX-ED02T) | --- | Brass (nickel-plated) | ||||
| Toothed washer | --- | Iron (zinc-plated) (except ZX-ED02T) | --- | Iron (zinc-plated) | ||||
| Preamplifier | PES | |||||||
| Accessories | Amplifier Mounting Brackets (ZX-XBE1), Instruction Manual | |||||||
*1: Resolution: The resolution is the deviation (±3σ) in the linear output when connected to the ZX-EDA Amplifier Unit. The above values indicate the deviations observed 30 minutes after the power is turned ON.
(The resolution is measured with OMRON's standard reference object at 1/2 of the measurement range with the ZX-EDA set for the maximum average count of 4,096 per period.)
The resolution is given at the repeat accuracy for a stationary workpiece, and is not an indication of the distance accuracy. The resolution may be adversely affected under strong electromagnetic fields.
*2: Linearity: The linearity is given as the error in an ideal straight line displacement output when measuring the standard reference object. The linearity and measurement values vary with the object being measured.
*3: Temperature characteristic: The temperature characteristic is measured with OMRON's standard reference object at 1/2 of the measurement range.
*4: The ambient temperature given is only for the sensor head. It is -10 to 60°C for the preamp.
*5: The value given is for an ambient temperature of 25°C.
*6: Do not use in moist environments because the case is not waterproof.
| Model | ZX-EDA11 | ZX-EDA41 |
|---|---|---|
| Measurement period *1 | 150 μs | |
| Possible average count settings | 1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1,024, 2,048, or 4,096 | |
| Linear output *2 | Current output: 4 to 20 mA/F.S., Max. load resistance: 300 Ω Voltage output: ± 4 V ( ± 5 V, 1 to 5 V *3), Output impedance: 100 Ω | |
| Judgement outputs (3 outputs: HIGH/PASS/LOW) | NPN open-collector outputs, 30 VDC, 50 mA max. Residual voltage: 1.2 V max. | PNP open-collector outputs, 30 VDC, 50 mA max. Residual voltage: 2 V max. |
| Zero reset input, timing input, reset input, judgement output hold input | ON: Short-circuited with 0-V terminal or 1.5 V or less OFF: Open (leakage current: 0.1 mA max.) | ON: Supply voltage short-circuited or supply voltage within 1.5 V OFF: Open (leakage current: 0.1 mA max.) |
| Function | - Number of display digit changes - Sample hold - Peak hold - Bottom hold, peak-to-peak hold - Self-peak hold - Self-bottom hold - Average hold - Delay hold - Zero reset - Initial reset - Linearity initialization - ON-delay timer - OFF-delay timer - One-shot timer - Previous value comparison - Non-measurement setting - Direct threshold value setting - Position teaching - Automatic teaching - Hysteresis width setting - Timing inputs - Reset input - Judgement output hold input - Monitor focus - Linear output correction - (A-B) calculations *4 - (A+B) calculations *4 - K-(A+B) calculation *4 - Mutual interference prevention *4 - Sensor disconnection detection - Zero reset memory - Zero reset indicator - Key lock | |
| Indications | Judgement indicators: High (orange), pass (green), low (yellow), 7-segment main digital display (red), 7-segment sub-digital display (yellow), power ON (green), zero reset (green), enable (green) | |
| Voltage influence (including Sensor) | 0.5% F.S. of linear output value at ±20% of power supply voltage | |
| Power supply voltage | 12 to 24 VDC ± 10%, Ripple (p-p): 10% max. | |
| Current consumption | 140 mA max. with power supply voltage of 24 VDC (with Sensor connected) | |
| Ambient temperature | Operating and storage: 0 to 50°C (with no icing or condensation) | |
| Ambient humidity | Operating and storage: 35% to 85% (with no condensation) | |
| Insulation resistance | 20 MΩ min. (at 500 DC) | |
| Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min | |
| Vibration resistance (destruction) | 10 to 150 Hz with 0.7-mm double amplitude for 80 min each in X, Y, and Z directions | |
| Shock resistance (destruction) | 300 m/s2, 3 times each in 6 directions (up, down, left, right, forward, backward) | |
| Connection method | Prewired (standard cable length: 2 m) | |
| Weight (packed state) | Approx. 350 g | |
| Materials | Case: PBT (polybutylene terephthalate), Cover: Polycarbonate | |
| Accessories | Instruction Manual | |
*1: The response time for the first linear output or judgment output is calculated as follows (with fixed sensitivity): Measurement period × (Average count setting + 1). The response time for the second and later outputs is the measurement period specified in the table.
*2: The output can be switched between a current output and voltage output using a switch on the bottom of the Amplifier Unit.
*3: Setting is possible via the monitor focus function.
*4: A Calculating Unit (ZX-CAL2) is required.
last update: April 25, 2013