OMRON F03-[] Switches
last update: October 7, 2015
• Standard Electrodes are made of stainless steel (SUS 304) and can be used in applications for purified water.
• SUS316 Electrodes can be used in applications where resistance to corrosion is required. Titanium and HAS Electrodes can be used in applications where resistance to acid is required.
• For applications where long electrodes are required, a connection nut and two Lock Nuts can be used to extend the electrodes 1 m at a time.
last update: October 7, 2015
If you have just landed here, this product OMRON F03-[] Switches,Switches is offered online by Tianin FLD Technical Co.,Ltd. This is an online store providing Switches at wholesale prices for consumers. You can call us or send enquiry, we would give you the prices, packing,deliverty and more detailed information on the F03-[] We cooperate with DHL,TNT,FEDEX,UPS,EMS,etc.They guarantee to meet your needs in terms of time and money,even if you need your OMRON F03-[]Switches tomorrow morning (aka overnight or next day air) on your desk, 2, 3 days or more.Note to international customers, YES, we ship worldwide.
E32-LT11N / LD11N / LR11NP Hex-shaped Fiber Unit/Features
NX-TC NX-series Temperature Control Unit/Features
K3MA-L Temperature Meter/Features
CJ1W-OC / OA / OD CJ-series Output Units/Features
CPM2C-SRT21 I/O Link Unit/Features
last update: September 24, 2012
No information is provided on the ratings and specifications of this product.
last update: September 24, 2012
Catalog Name | Catalog Number [size] | Last Update | |
---|---|---|---|
![]() | - [457KB] | Aug 01, 201820180801 | F03-[] Data Sheet |
![]() | - [206KB] | Mar 01, 201820180301 | Safety Precautions for Electrodes and Electrode Holders |
last update: August 1, 2018
Material indications are provided on all OMRON electrodes, connection nuts, and Lock Nuts.
Select an electrode appropriate for the type of liquid. Refer to Technical Guide for Level Controllers.
Model | Material | Weight (g) | Material indication lines | |
---|---|---|---|---|
F03-01 SUS304 ELECTRODE | SUS304 | Approx. 170 | 1 line | ![]() |
F03-01 SUS316 ELECTRODE | SUS316 | 2 lines | ||
F03-01 HAS B ELECTRODE | N10665 * | Approx. 195 | 3 lines | |
F03-01 HAS C ELECTRODE | N10276 * | Approx. 190 | 4 lines | |
F03-01 TITANIUM ELECTRODE | Titanium | Approx. 100 | 5 lines |
* UNS No. (Unified Numbering System No.) is an international metal designation system that specifies a unique number
for each material.
Electrodes are insulated with a plastic sheath to prevent them from touching each other and to isolate them from debris in the liquid.
Before application, strip back about 10 cm of the sheath at the end to ensure sufficient conductivity.
Model | Sheath |
---|---|
F03-01 SUS304 | Vinyl Tubing |
F03-01 SUS304 FLUORORESIN | Fluororesin Tubing |
F03-01 SUS316 | Vinyl Tubing |
F03-01 SUS316 FLUORORESIN | Fluororesin Tubing |
Note: Tubing comes in 1-m lengths with a sheath thickness of 0.5 mm.
Model | Material | Weight (g) | Material indication |
---|---|---|---|
F03-02 SUS304 *1 | SUS303 (Equivalent to SUS304) | Approx. 12 | Blank |
F03-02 SUS316 *1 | SUS316 | 6 | |
F03-02 HAS B | N10665 *2 | Approx. 20 | B |
F03-02 HAS C | N10276 *2 | C | |
F03-02 TITANIUM | Titanium | Approx. 6 | T |
*1. Spring washers made of the same material are included with the F03-02 SUS304 and F03-02 SUS316.
Spring washers are not included with the other models.
OMRON does not sell spring washers by themselves.
*2. UNS No. (Unified Numbering System No.) is an international metal designation system that specifies a unique
number for each material.
An Electrode Set consists of an electrode, a connecting nut, and two Lock Nuts.
Set model | Components | No. of parts in an set | Weight (g) |
---|---|---|---|
F03-60 SUS304 | F03-01 SUS304 ELECTRODE | 1 | Approx. 190 |
F03-02 SUS304 | 1 | ||
F03-03 SUS304 | 2 | ||
F03-60 SUS316 | F03-01 SUS316 ELECTRODE | 1 | |
F03-02 SUS316 | 1 | ||
F03-03 SUS316 | 2 |
Note: HAS and titanium Electrodes do not come in sets.
Model | Material | Weight (g) | Material indication |
---|---|---|---|
F03-03 SUS304 *1 | SUS303 (Equivalent to SUS304) | Approx. 2 | Blank |
F03-03 SUS316 *1 | SUS316 | 6 | |
F03-03 HAS B | N10665 *2 | Approx. 5 | B |
F03-03 HAS C | N10276 *2 | C | |
F03-03 TITANIUM | Titanium | Approx. 2 | T |
*1. Only SUS304 and SUS316 Lock Nuts come with spring washers made of the same material. HAS B, HAS C and
TITANIUM don't come with spring washer.
*2. UNS No. (Unified Numbering System No.) is an international metal designation system that specifies a unique
number for each material.
When long electrodes are required, use Separators at each joint (every 1 m) to prevent the Electrodes from touching each other.
Use a 1-pole Separator with BF Electrode Holders. The five-pole model can be used with PS-5S and PS-4S Electrode Holders.
Separators cannot be used with PS-31 Electrode Holders.
Model | No. of Electrodes | Dimensions | Applicable Electrode Holder | Weight (g) | Material | Operating Temperature |
---|---|---|---|---|---|---|
F03-14 1P | 1 | ![]() | BF-[](R) | Approx. 15 | Ceramic | 250 ° C max. |
F03-14 3P | 3 | ![]() | PS-3S(R) | Approx. 30 | ||
F03-14 5P | 5 | ![]() | PS-4S(R) PS-5S(R) |
Note: The Electrode Separators cannot be used unless the Electrodes are coupled.
Note: When using two or more Separators, be careful with the mounting direction of the connecting nut screws which connect electrodes. Avoid the screws from touching each other.
Application | Model |
---|---|
Protective Cover (for PS-[]S and BF-3/-5) | F03-11 |
Mounting Frame (for PS-[]S) | F03-12 |
Mounting Frame for Installing in Concrete (for PS-[]S(R)) | F03-13 |
Dust-proof Rubber Cap (for PS-31) | F03-31 |
last update: August 1, 2018
last update: October 07, 2015
F03-02
Titanium
Note: 1. Dimension when mounting Electrodes.
2. Clamp screws are not provided for HAS B, HAS C, or titanium models. F03-03 Lock Nuts are used to
mount Electrodes.
last update: October 07, 2015