• Standard Electrodes are made of stainless steel (SUS 304) and can be used in applications for purified water. 

• SUS316 Electrodes can be used in applications where resistance to corrosion is required. Titanium and HAS Electrodes can be used in applications where resistance to acid is required. 

• For applications where long electrodes are required, a connection nut and two Lock Nuts can be used to extend the electrodes 1 m at a time.

Purchase the OMRON Electrode Holders / Electrodes Please fill in the following

Title:

Email:

Tel:

Content:

Verification code:

If you have just landed here, this product OMRON F03-[] Switches,Switches is offered online by Tianin FLD Technical Co.,Ltd. This is an online store providing Switches at wholesale prices for consumers. You can call us or send enquiry, we would give you the prices, packing,deliverty and more detailed information on the F03-[] We cooperate with DHL,TNT,FEDEX,UPS,EMS,etc.They guarantee to meet your needs in terms of time and money,even if you need your OMRON F03-[]Switches tomorrow morning (aka overnight or next day air) on your desk, 2, 3 days or more.Note to international customers, YES, we ship worldwide.

E32-LT11N / LD11N / LR11NP Hex-shaped Fiber Unit/Features
NX-TC NX-series Temperature Control Unit/Features
K3MA-L Temperature Meter/Features
CJ1W-OC / OA / OD CJ-series Output Units/Features
CPM2C-SRT21 I/O Link Unit/Features


OMRON F03-[] specification

F03-[] Electrodes and Accessories/Specifications

No information is provided on the ratings and specifications of this product.


OMRON F03-[] catalog

F03-[] Electrodes and Accessories/Catalog

  • Catalog
  • CAD

English

Global Edition

For ordering in Singapore, please note some product models not sold in Singapore may be included in the following catalog(s) for our global customers.

*It is recommended to select “Save” from the right-click due to large size of catalog PDF data.

Catalog Name Catalog Number
[size]
Last Update
F03-[] Data Sheet -
[457KB]
Aug 01, 201820180801 F03-[] Data Sheet
Safety Precautions for Electrodes and Electrode Holders -
[206KB]
Mar 01, 201820180301 Safety Precautions for Electrodes and Electrode Holders


OMRON F03-[] lineup

F03-[] Electrodes and Accessories/Lineup

Material indications are provided on all OMRON electrodes, connection nuts, and Lock Nuts.

Electrodes

Select an electrode appropriate for the type of liquid. Refer to Technical Guide for Level Controllers.

ModelMaterialWeight (g)Material indication lines
F03-01 SUS304 ELECTRODESUS304Approx. 1701 line257_lu_1_1
F03-01 SUS316 ELECTRODESUS3162 lines
F03-01 HAS B ELECTRODEN10665 *Approx. 1953 lines
F03-01 HAS C ELECTRODEN10276 *Approx. 1904 lines
F03-01 TITANIUM ELECTRODETitaniumApprox. 1005 lines

* UNS No. (Unified Numbering System No.) is an international metal designation system that specifies a unique number
  for each material.

Insulated Electrodes

Electrodes are insulated with a plastic sheath to prevent them from touching each other and to isolate them from debris in the liquid.
Before application, strip back about 10 cm of the sheath at the end to ensure sufficient conductivity.

ModelSheath
F03-01 SUS304Vinyl Tubing
F03-01 SUS304 FLUORORESINFluororesin Tubing
F03-01 SUS316Vinyl Tubing
F03-01 SUS316 FLUORORESINFluororesin Tubing

Note: Tubing comes in 1-m lengths with a sheath thickness of 0.5 mm.

Connecting Nuts

ModelMaterialWeight (g)Material indication
F03-02 SUS304 *1SUS303 (Equivalent to SUS304)Approx. 12Blank
F03-02 SUS316 *1SUS3166
F03-02 HAS BN10665 *2Approx. 20B
F03-02 HAS CN10276 *2C
F03-02 TITANIUMTitaniumApprox. 6T

*1. Spring washers made of the same material are included with the F03-02 SUS304 and F03-02 SUS316.
       Spring washers are not included with the other models.
       OMRON does not sell spring washers by themselves.
*2. UNS No. (Unified Numbering System No.) is an international metal designation system that specifies a unique
       number for each material.

Electrode Sets

An Electrode Set consists of an electrode, a connecting nut, and two Lock Nuts.

Set modelComponentsNo. of parts in an setWeight (g)
F03-60 SUS304F03-01 SUS304 ELECTRODE1Approx. 190
F03-02 SUS3041
F03-03 SUS3042
F03-60 SUS316F03-01 SUS316 ELECTRODE1
F03-02 SUS3161
F03-03 SUS3162

Note: HAS and titanium Electrodes do not come in sets.

Lock Nuts

ModelMaterialWeight (g)Material indication
F03-03 SUS304 *1SUS303 (Equivalent to SUS304)Approx. 2Blank
F03-03 SUS316 *1SUS3166
F03-03 HAS BN10665 *2Approx. 5B
F03-03 HAS CN10276 *2C
F03-03 TITANIUMTitaniumApprox. 2T

*1. Only SUS304 and SUS316 Lock Nuts come with spring washers made of the same material. HAS B, HAS C and
       TITANIUM don't come with spring washer.
*2. UNS No. (Unified Numbering System No.) is an international metal designation system that specifies a unique
       number for each material.

Electrode Separators

When long electrodes are required, use Separators at each joint (every 1 m) to prevent the Electrodes from touching each other.
Use a 1-pole Separator with BF Electrode Holders. The five-pole model can be used with PS-5S and PS-4S Electrode Holders.
Separators cannot be used with PS-31 Electrode Holders.

ModelNo. of
Electrodes
DimensionsApplicable
Electrode Holder
Weight (g)MaterialOperating
Temperature
F03-14 1P1257_lu_6_1BF-[](R)Approx. 15Ceramic250 ° C max.
F03-14 3P3257_lu_6_2PS-3S(R)Approx. 30
F03-14 5P5257_lu_6_3PS-4S(R)
PS-5S(R)

Note: The Electrode Separators cannot be used unless the Electrodes are coupled.

F03-[] Lineup 18

Note: When using two or more Separators, be careful with the mounting direction of the connecting nut screws which connect electrodes. Avoid the screws from touching each other.

Accessories (Order Separately)

ApplicationModel
Protective Cover (for PS-[]S and BF-3/-5)F03-11
Mounting Frame (for PS-[]S)F03-12
Mounting Frame for Installing in Concrete (for PS-[]S(R))F03-13
Dust-proof Rubber Cap (for PS-31)F03-31


OMRON F03-[] dimension

F03-[] Electrodes and Accessories/Dimensions

Electrode

F03-01

F03-[] Dimensions 2

Lock Nut

F03-03
SUS304
SUS316
Titanium

F03-[] Dimensions 4

F03-03
HAS B
HAS C

F03-[] Dimensions 5

Connecting nut

F03-02
SUS304
SUS316

F03-[] Dimensions 7

F03-02
HAS B
HAS C

F03-[] Dimensions 8

F03-02
Titanium

F03-[] Dimensions 9

Note: 1. Dimension when mounting Electrodes.
           2. Clamp screws are not provided for HAS B, HAS C, or titanium models. F03-03 Lock Nuts are used to
                 mount Electrodes.