OMRON CS1W-LCB01 / LCB05 Automation Systems
last update: November 21, 2013
Increasing amounts of information, standardization, and open standards form the basis for achieving hardware and networking capabilities for process control.
A wide range of software that can be easily used by design, development, and maintenance personnel makes operating and maintaining the system far easier.
*For details on the CJ Series, refer to the Loop-control CPU Units Catalog (R128-E1-01).
Windows is a registered trademark of the Microsoft Corporation. DeviceNet, DeviceNet Safety, CompoNet, and EtherNet/IP are registered trademarks of the ODVA.
Other company names and product names are the trademarks or registered trademarks of the respective companies.
Systems are large, meaning high initial costs.
The over-spec nature of a distributed control system (DCS) increased costs.
PLCs, however, could not provide the required process control capabilities, and signal conversion with isolators and other devices was required for I/O.
It was just not possible to achieve the ideal system for a specific application.
Down-sizing
Cut costs, Save space, Reduce labor
PLCs provide the some of the functions and performance of DCS while also providing the advanced features of PLCs: Open specs, easy maintenance, and cost performance.
A wide range of Isolated-type Analog Units helps to save space and greatly reduces system costs.
Running costs are high because maintenance and modifications require specialists.
The manufacturer must be relied upon for everything from system construction to maintenance.
Even simple changes to parameters cannot be performed in-house.
And, it's nearly impossible to use generalpurpose devices and software (such as HMI devices or Windows-based software) when modifying the system.
Easy Engineering
Engineering is simple when you can program with function blocks.
Paste function blocks in a window just like you were creating a flow sheet, and then connect the blocks with the mouse to graphically program a wide range of process control.
And with a PLC, it's easy to incorporate general-purpose HMI devices and software (such as touch panels and SCADA software).
Increase the reliability of the facilities and devices with a Duplex PLC-based Process Control System.
If an error occurs in the active CPU Unit, the standby CPU Unit takes over in an instant (using the hot standby method) so that system operation continues essentially unaffected.
Other duplex variations are also possible.
For example, instead of duplexing the CPU Unit, Power Supply Unit, and Controller Link Unit, a system can be constructed with a Single-CPU Unit and only a duplex Power Supply Unit or only a duplex Controller Link Unit.
A duplex system means rapid recovery for errors.
Replace Units with power supplied or even while the system is running, including CPU Units (Duplex-CPU system), Power Supply Units, Communications Units, Basic I/O Units, and Special I/O Units.
Excessive installation space is required.
When using more than one controller for multi-loop control, the control panel is just too big.
And specification changes required altering the control panel, making changes difficult.
Down-sizing
Consolidate the functions of many controllers
Programming is as simple as combining the function blocks required by the application.
To increase the number of controlled loops, just add them to the program.
HMI windows can also be created easily using a wide range of utility software.
Programming communications with the controllers is extremely difficult.
Communications must be programmed to input data to the PLC.
And communications time can restrict control performance.
The more controllers that are used, the more difficult maintenance becomes.
Easy Engineering
Advanced controller functions are built into the CS1 PLCs. No programming is required for communications.
The Loop Control Boards and Units were designed for the CS1 PLCs and require no communications programming.
High-speed, flexible data links can be created with the PLC to increase control performance.
last update: November 21, 2013
If you have just landed here, this product OMRON CS1W-LCB01 / LCB05 Automation Systems,Automation Systems is offered online by Tianin FLD Technical Co.,Ltd. This is an online store providing Automation Systems at wholesale prices for consumers. You can call us or send enquiry, we would give you the prices, packing,deliverty and more detailed information on the CS1W-LCB01 / LCB05 We cooperate with DHL,TNT,FEDEX,UPS,EMS,etc.They guarantee to meet your needs in terms of time and money,even if you need your OMRON CS1W-LCB01 / LCB05Automation Systems tomorrow morning (aka overnight or next day air) on your desk, 2, 3 days or more.Note to international customers, YES, we ship worldwide.
NY51[]-A Industrial PC Platform NY-series IPC Programmable Multi-Axis Controller/Features
MX-Z2000H Series Fiber Laser Marker/Features
CJ1W-EIP21 CJ-series EtherNet/IP Unit/Features
CRT1-AD04 / DA02 Analog I/O Slave Units/Features
K8AK / K8DS Series Measuring & Monitoring Relays/Features
last update: December 3, 2018
Item | Specifications | |||
---|---|---|---|---|
Name | Loop Control Boards | |||
Unit classification | CS-series Inner Boards | |||
Model number | CS1W-LCB01: Standard Inner Board | CS1W-LCB05(-GTC): Special Inner Board | LCB05D: Duplex Inner Board | |
Applicable CPU Units | CS1G/H-CPU[][]H CS1D-CPU[][]S/SA (See note 1.) | CS1G/H-CPU[][]H CS1D-CPU[][]S/SA (See note 1.) | Built into the CS1D-CPU6[]P. | |
Mounting location | Inner Board slot in CPU Unit | |||
Number of Boards/Units | 1 Board max. per CPU Unit | |||
Data exchange with CPU Unit | I/O memory | User Link Tables: ITEM data for function blocks can be allocated in any part of I/O memory (CIO, WR, HR, or DM Areas, or EM Area bank 0). | ||
All data | HMI function used to allocate function block ITEM data for Control, Operation, and External Controller blocks in the specified bank of the EM Area in the CPU Unit. (Default: Bank 0) | |||
Setting switches | None | |||
Indicators | 3 LEDs: RUN, ready, and communications port send/receive | |||
Front panel connections | RS-232C port x 1 (The CS1D-LCB05D cannot be used to connect to the ES100X Controller.) | |||
Data backup | By super capacitor: All function block data (including sequence tables and step ladder instructions) | |||
Battery /capacitor life | 24 hours at 25°C (life shortened by use at higher temperatures) | |||
Data storage in flash memory | Function block data (RAM data backup and recovery can be performed whenever necessary.) Error log data | |||
Effect on CPU Unit cycle time | 0.8 ms max. | 25 ms max. (See note 2.) | ||
Current consumption (supplied from Power Supply Unit) | 220 mA at 5 V DC (Increased by 150 mA when NT-AL001-E Link Adapter is used.) | |||
Dimensions | 34.5 × 130 × 100.5 mm (W × H × D) | |||
Weight | 100g max. | |||
Standard accessories | None |
Note: 1. A Loop Control Board Unit Ver. 1.5 or later is required for use. Do not use a Loop Control Board with a unit version earlier than 1.5.
Note: 2. During duplex initialization: 2.1 s max.
last update: December 3, 2018
last update: December 3, 2018
Unit name | Specifications | Model |
---|---|---|
Loop Control Boards | No. of function blocks: 50 blocks max. | CS1W-LCB01 |
No. of function blocks: 500 blocks max. | CS1W-LCB05 | |
CS1W-LCB05-GTC |
Note: Use a CS1D-CPU6[]P CSID Process-control CPU Unit (for Duplex-CPU System) when duplex operation is required.
Use the CS1W-LCB0[] Loop Control Board when using a CS1D CPU Unit for a Single-CPU System
Product name | Specifications | Model | ||
---|---|---|---|---|
No. of licenses | Media | |||
FA Integrated Tool Package CX-One Ver. 4.[] | The CX-One is a comprehensive software package that integrates Support Software for OMRON PLC's and components. CX-One runs on the following OS. OS: Windows XP (Service Pack 3 or higher, 32-bit version)/Windows Vista (32-bit/64-bit version)/ Windows 7 (32-bit/64-bit version)/Windows 8 (32-bit/64-bit version)/Windows 8.1 (32-bit/64-bit version)/Windows 10 (32-bit/64-bit version) CX-One version 4.[] includes CX-Process Tool Ver.5.[] and FacePlate Auto-Builder for NS Ver.3.[]. For details, refer to the CX-One Introduction Guide (Cat. No. R134). | --- (Media only) * | DVD | CXONE-AL00D-V4 |
1 license | CXONE-AL01D-V4 | |||
3 licenses | CXONE-AL03D-V4 | |||
10 licenses | CXONE-AL10D-V4 | |||
30 licenses | CXONE-AL30D-V4 | |||
50 licenses | CXONE-AL50D-V4 |
Note: Site licenses are available for users who will run CX-One on multiple computers. Ask your OMRON sales
representative for details.
* The CXONE-AL00D-V4 contains only the DVD installation media for users who have purchased the CX-One Version 4.[]
and does not include the license number. Enter the license number of the CX-One Version 4.[] when installing.
(The license number of the CX-One Version 3.[] or lower cannot be used for installation.)
last update: December 3, 2018
Catalog Name | Catalog Number [size] | Last Update | |
---|---|---|---|
![]() | P051-E1-10 [3438KB] | Dec 03, 201820181203 | CS Series Catalog |
last update: November 21, 2013
last update: November 21, 2013