OMRON NS-NSRCL1 / 3 / 10 Machine Monitoring Software NS-Runtime/Features Programmable Terminals--OMRON NS-NSRCL1 / 3 / 10 Online Store

OMRON NS-NSRCL1 / 3 / 10Automation Systems/ Programmable Terminals/Copyright Statement

OMRON NS-NSRCL1 / 3 / 10 Automation Systems

OMRON NS-NSRCL1 / 3 / 10 Dimensions

/Images/l_1907-25-118998-198x198.jpg

NS-NSRCL[] (NS-Runtime)

Achieve machine/line monitoring and data logging on your office computer.

Machine Viewer

Machine monitoring in an office environment.
There is no need to create complex host applications.
Moreover, when an alarm occurs, a PDF file can be displayed as maintenance information. NS Series screens can be reused on the computer, and screens can be also newly created independently of touch panels at the production site.

NS-NSRCL1 / 3 / 10 Features 3

Wide Screen

Computer output can be displayed on another wide-screen monitor. XGA (1,024 x 768 dots) and up to a a maximum screen size of 3,840 x 2,400 is supported. Alarms occurring in devices or the line can be monitored.

NS-NSRCL1 / 3 / 10 Features 5

Note: The resolution that can be displayed depends on the computer. An input function for displaying the computer
           screen is required at the display monitor.

Data Logger

Log large amounts of data using a personal computer. Data can be logged through background processing, with up to 160,000 points stored in one file. The logged data is stored in CSV format, and data can be displayed on data log graphs.

NS-NSRCL1 / 3 / 10 Features 8

Example: 160,000 Points
Data can be logged for approximately 7.4 days, assuming data is logged every two seconds for 12 hours a day. By using automatic file saving, data logging can be continued even longer than 7.4 days.

Recipe Handling

Checking machine data or switching processes from a host computer is easy. Parameter groups in the PLC can be transferred together to a computer, and the transferred data can be checked and edited in CSV format, e.g., using Excel. The edited data can then be transferred together back to the PLC.

NS-NSRCL1 / 3 / 10 Features 9

Easy Installation

To get started, just install the NS-Runtime in the computer and place the screen data in the applicable folder. NS/NSJ-series screens and NS-Runtime screens can all be managed using one single tool.
Note: The NS-Runtime will operate in a computer environment even if the CX-Designer installed is not installed. The
           hardware key (USB dongle) that is supplied with the NS-Runtime is required for operation.

NS-NSRCL1 / 3 / 10 Features 10

Application Startup Function

User applications can be started from NS-Runtime.
Applications can be started simply by pressing buttons on the screen.

NS-NSRCL1 / 3 / 10 Features 11

Note 1: If the screen data is converted for the NS Series, NS-Series PT system versions must be 8.1 or earlier. The
             screen data of system version 8.2 can not be converted for the NS-Runtime.
Note 2: Do not use this product for 24-hour operation in an FA environment. OMRON shall not be responsible if the
             computer or application does not operate properly due to noise or other causes.
             OMRON shall not be responsible for any problems that may be caused by any applications other than OMRON
             products.

Purchase the OMRON Copyright Statement Please fill in the following

Title:

Email:

Tel:

Content:

Verification code:

If you have just landed here, this product OMRON NS-NSRCL1 / 3 / 10 Automation Systems,Automation Systems is offered online by Tianin FLD Technical Co.,Ltd. This is an online store providing Automation Systems at wholesale prices for consumers. You can call us or send enquiry, we would give you the prices, packing,deliverty and more detailed information on the NS-NSRCL1 / 3 / 10 We cooperate with DHL,TNT,FEDEX,UPS,EMS,etc.They guarantee to meet your needs in terms of time and money,even if you need your OMRON NS-NSRCL1 / 3 / 10Automation Systems tomorrow morning (aka overnight or next day air) on your desk, 2, 3 days or more.Note to international customers, YES, we ship worldwide.

NY51[]-A Industrial PC Platform NY-series IPC Programmable Multi-Axis Controller/Features
3G3RX-V1 High-function General-purpose Inverters/Features
E2K-C Long-distance type/Features
G3PA Solid State Relays/Features
Cobra 650 SCARA Robots/Features


OMRON NS-NSRCL1 / 3 / 10 catalog

NS-NSRCL1 / 3 / 10 Machine Monitoring Software NS-Runtime/Catalog

  • Catalog
  • Manual

English

Global Edition

For ordering in Singapore, please note some product models not sold in Singapore may be included in the following catalog(s) for our global customers.

*It is recommended to select “Save” from the right-click due to large size of catalog PDF data.

Catalog Name Catalog Number
[size]
Last Update
NS Series Catalog V405-E1-16
[35366KB]
Oct 01, 201820181001 NS Series Catalog


OMRON NS-NSRCL1 / 3 / 10 dimension

NS-NSRCL1 / 3 / 10 Machine Monitoring Software NS-Runtime/Dimensions

No information is provided on the dimensions of this product.


OMRON NS-NSRCL1 / 3 / 10 specification

NS-NSRCL1 / 3 / 10 Machine Monitoring Software NS-Runtime/Specifications

No information is provided on the Ratings and Specifications of this product.


OMRON NS-NSRCL1 / 3 / 10 lineup

NS-NSRCL1 / 3 / 10 Machine Monitoring Software NS-Runtime/Lineup

International Standards

  • The standards are availabled as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
  • Contact your OMRON representative for further details and applicable conditions for these standards.

NS-Runtime

Product nameSpecificationsMediaModelStandards
NS-RuntimeNS-Runtime Installer, PDF manual, hardware key *1licenseCDNS-NSRCL1---
3 licensesNS-NSRCL3
10 licensesNS-NSRCL10

Note: A hardware key (USB dongle) is required for NS-Runtime operation.

System Requirements

ItemSpecifications
OS *Windows 7 (32-bit/64-bit version)/Windows 8 (32-bit/64-bit version)/Windows 10 (32-bit/64-bit version)
CPUCeleron, 1.3 GHz or higher (Recommended)
Memory sizeHDD: 50 MB min., RAM: 512 MB min. (Windows 7: 1 GB min.).
50 MB is required for the Runtime alone. (An additional 280 MB is required if CX-Server is not already
installed.)

* Ver. 1.30 or later of NS Runtime do not support Windows XP (Service Pack 3 or higher) and Windows Vista.