OMRON H7HP Control Components
last update: December 19, 2013
• Large, easy-to-read displays: 15-mm-high characters for 6-digit models; 12-mm-high characters for 8-digit models.
• High-visibility, negative transmissive LCD display with built-in red LED backlight at low power consumption.
• IP66 with oil resistance and NEMA4 are achieved by unifying the front with the casing case and using oil-resistant materials and parts.
• Compact (66 mm) body.
• Switch 6-digit models between total counter and time counter operation.
• Just change a switch setting for either an NPN or PNP input.
• Supports both external resetting and manual resetting.
• Finger-protection terminal block cover prevents electrical shock and conforms to VDE0106, Part 100.
• Safety standards: UL, CSA, EMC (EN 61326), CE Marking.
last update: December 19, 2013
If you have just landed here, this product OMRON H7HP Control Components,Control Components is offered online by Tianin FLD Technical Co.,Ltd. This is an online store providing Control Components at wholesale prices for consumers. You can call us or send enquiry, we would give you the prices, packing,deliverty and more detailed information on the H7HP We cooperate with DHL,TNT,FEDEX,UPS,EMS,etc.They guarantee to meet your needs in terms of time and money,even if you need your OMRON H7HPControl Components tomorrow morning (aka overnight or next day air) on your desk, 2, 3 days or more.Note to international customers, YES, we ship worldwide.
V500-R2 Laser-type Bar Code Reader/Features
E3T Ultracompact, Ultrathin Photoelectric Sensor with Built-in Amplifier/Features
H3YN-[]-B Solid-state Timer/Features
CJ1W-SCU CJ-series Serial Communications Units/Features
CRT1-[]D08(-1) / []D16(-1) / ROS[] / ROF[] Digital I/O Slave Units with Screw Terminal Blocks (2-...
last update: July 20, 2016
Item | 6-digit total counter/time counter | 8-digit total counter | |||
---|---|---|---|---|---|
H7HP-A | H7HP-AD | H7HP-C8 | H7HP-C8D | ||
Rated supply voltage | 100 to 240 VAC (50/60 Hz) | 12 to 24 VDC *1 | 100 to 240 VAC (50/60 Hz) | 12 to 24 VDC *1 | |
External power supply | 50 mA at 12 VDC | --- | 50 mA at 12 VDC | --- | |
Operating voltage range | 85% to 110% of rated supply voltage | ||||
Power consumption | 100 to 240 VAC: 6.5 VA max. 12 to 24 VDC: 0.6 W max. | ||||
Dimensions | 72 x 36 x 66 mm (W x H x D) | ||||
Mounting method | Flush mounting | ||||
External connections | Screw terminals | ||||
Degree of protection | Panel surface: IP66 with oil resistance, NEMA 4 (indoors). Panel surface only: IEC IP66. IEC IP66 | ||||
Display | 7-segment, negative transmissive LCD (with red backlight) | ||||
Digits | 6 digits (15-mm-high characters) | 8 digits (12-mm-high characters) | |||
Function | Total counter/time counter (selected via DIP switch) | Total counter | |||
Input mode | Up/down (individual) (total counter), or accumulative (time counter) | Up/down (individual) | |||
Max. counting speeds | 30 Hz or 5 kHz (selected via DIP switch) | ||||
Counting range | -99999 to 999999 | -9999999 to 99999999 | |||
Time specification | 0.1 to 99999.9 h/1 s to 99 h 59 min 59 s (selected via DIP switch) | --- | |||
Timing accuracy | ±100 ppm (-10°C to 55°C) | --- | |||
Memory backup | EEP-ROM (overwrites: 200,000 times min.) that can store data for 20 years min. | ||||
Input | Input signals | Count 1/start, count 2/gate, reset, and key protection *2 | |||
Input method | No-voltage input (NPN transistor input) or voltage input (PNP transistor input) (selected via DIP switch) | ||||
Count, start, gate, reset | No-voltage input (NPN transistor input) Short-circuit (ON) impedance: 1 kΩ max. Short-circuit (ON) residual voltage: 2 VDC max. Open (OFF) impedance: 100 kΩ min. Voltage input (PNP transistor input) Short-circuit (ON) impedance: 1 kΩ max. ON voltage: 9 to 24 VDC OFF voltage: 5 VDC max. Open (OFF) impedance: 100 kΩ min. | ||||
Key protection | No-voltage input (NPN transistor input) Short-circuit (ON) impedance: 1 kΩ max. Short-circuit (ON) residual voltage: 0.5 VDC max. Open (OFF) impedance: 100 kΩ min. | ||||
Input response speed | Reset | Time counter: 20 ms; total counter: 20 ms or 1 ms (automatically switched according to counting speed) | |||
Start | Time counter: 20 ms | ||||
Key protection | Approx. 1 s | Approx. 1 s | |||
Reset system | External and manual resets |
*1. Contains 20% ripple (p-p) max.
*2. Only a non-voltage input (NPN transistor) is possible for the key protection input. The key protection input will be a
non-voltage input even if the NPN/PNP input mode is set to PNP. Key protection is used to prohibit operating the
Reset Key. The reset input terminals will still be functional.
Insulation resistance | 100 MΩ min. (at 500 VDC) |
---|---|
Dielectric strength | 2,000 VAC, 50/60 Hz for 1 min between current-carrying terminal and exposed non-current- carrying metal parts (AC model) 1,000 VAC, 50/60 Hz for 1 min between current-carrying terminal and exposed non-current- carrying metal parts (DC model) 2,000 VAC, 50/60 Hz for 1 min between power terminals and control input terminals (AC model) |
Impulse withstand voltage | 3 kV (between power terminals) (1 kV for 12-to-24-VDC models) 4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) (1.5 kV for 12-to-24-VDC models) |
Noise immunity | ±1.5 kV (between AC power terminals), ±480 V (between DC power terminals), ±480 V (between input terminals); square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) |
Static immunity | Display: Malfunction: 8 kV, Destruction: 15 kV DIP switch: Malfunction: 4 kV, Destruction: 8 kV |
Vibration resistance | Destruction: 10 to 55 Hz with 0.75-mm single amplitude, 2 hours each in three directions Malfunction: 10 to 55 Hz with 0.5-mm single amplitude, 10 minutes each in three directions |
Shock resistance | Destruction: 294 m/s2 each in three directions Malfunction: 196 m/s2 each in three directions |
Ambient temperature | Operating: -10°C to 55°C (with no icing) Storage: -25°C to 65°C (with no icing) |
Ambient humidity | Operating: 35% to 85% |
EMC | (EMI) EN61326-1 *1 Emission Enclosure: EN55011 Group 1 class A Emission AC Mains: EN55011 Group 1 class A (EMS) EN61326-1 *1 Immunity ESD: EN61000-4-2: 4 kV contact discharge (level 2); 8 kV air discharge (level 3) Immunity RF-interference: EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3); 10 V/m (Pulse-modulated, 900 MHz ±5 MHz) (level 3) Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (according to EN61000-6-2) Immunity Burst: EN61000-4-4: 2 kV power-line (level 3); 2 kV I/O signal-line (level 4) Immunity Surge: EN61000-4-5: 1 kV line to lines (power and output lines) (level 2); 2 kV line to ground (power and output lines) (level 3) Immunity Voltage Dip/Interruption: EN61000-4-11: 0.5 cycle, 100% (rated voltage) |
Approved standards | UL508 *2, CSA C22.2 No.14 *2, conforms to EN61010-1, VDE0106/P100 |
Case color | Rear section: Gray smoke; Front section: 5Y7/1 (light gray) or N1.5 (black) |
Weight | Approx. 115 g |
*1. Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)
*2. UL508 and CAN/CSA-C22.2 No.14 certification conditions
• Power supply 100 to 240VAC types
Ambient temperature 30°C Single mounting
• Power supply 12 to 24VDC types
Ambient temperature 40°C Single mounting
last update: July 20, 2016
Catalog Name | Catalog Number [size] | Last Update | |
---|---|---|---|
![]() | - [680KB] | Jul 20, 201620160720 | H7HP Data Sheet |
last update: September 24, 2012
Supply voltage | 6-digit total counter/time counter | 8-digit total counter | ||
---|---|---|---|---|
Light gray | Black | Light gray | Black | |
100 to 240 VAC | H7HP-A | H7HP-AB | H7HP-C8 | H7HP-C8B |
12 to 24 VDC | H7HP-AD | H7HP-ADB | H7HP-C8D | H7HP-C8DB |
last update: September 24, 2012
last update: September 24, 2012