OMRON D4E-[]N Switches
last update: December 19, 2013
• Flat springs with an improved lever ratio of the built-in switch ensure smooth snap action and long life expectancy.
• Protection cover protects the built-in switch from dust and oil. Plunger incorporates a tough seal cap that lasts for a long time.
• One touch connector eliminates need for tedious wiring operations and reduces downtime for wiring and maintenance (models with standard, easy-to-use screw terminals are also available).
• Minute load model with gold cladding is optimal for electronic control.
• Molded terminal types as well as molded terminal types with operating indicator lamps are available for screw terminal systems.
• Approved by EN, UL, CSA, and CCC (Chinese standard). (Ask your OMRON representative for Information on approved models.)
• No difference in mounting pitch and characteristics between D4E-[]N and D4E models.
last update: December 19, 2013
If you have just landed here, this product OMRON D4E-[]N Switches,Switches is offered online by Tianin FLD Technical Co.,Ltd. This is an online store providing Switches at wholesale prices for consumers. You can call us or send enquiry, we would give you the prices, packing,deliverty and more detailed information on the D4E-[]N We cooperate with DHL,TNT,FEDEX,UPS,EMS,etc.They guarantee to meet your needs in terms of time and money,even if you need your OMRON D4E-[]NSwitches tomorrow morning (aka overnight or next day air) on your desk, 2, 3 days or more.Note to international customers, YES, we ship worldwide.
E3X-DRT21-S VER.3 Fiber Amplifier Sensor Communication Unit/Features
E5EC, E5EC-B Digital Temperature Controller (48 x 96 mm)/Features
WS02-CFDC1, 3G8E2-DRM21-V1 DeviceNet Configurator/Features
K8DT-AW Single-phase Overcurrent/Undercurrent Relay/Features
K8DT-LS Conductive Level Controller/Features
last update: March 07, 2013
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
*1. A 5.8-dia. to 7.6-dia. cable can be applied to the seal rubber for the lead wire outlet.*2. A 3-m lead wire cable equivalent to the 3-conductor VCTF S-FLEX cable (0.75 mm2, 7 mm in dia.) is provided.
last update: March 07, 2013
Catalog Name | Catalog Number [size] | Last Update | |
---|---|---|---|
![]() | - [1780KB] | Jan 05, 201720170105 | D4E-[]N Data Sheet |
last update: January 05, 2017
Type | One-touch connector type | Screw terminal type | |||||
---|---|---|---|---|---|---|---|
General- purpose | Micro load | General- purpose without cable | Micro load without cable | General- purpose with cable | Micro load with cable | ||
![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||
Actuator | Model | Model | Model | Model | Model | Model | |
Roller plunger | ![]() | D4E-1A[]0N | D4E-2A10N | D4E-1A20N | D4E-2A20N | D4E-1A21N | D4E-2A21N |
Crossroller plunger | ![]() | D4E-1B[]0N | D4E-2B10N | D4E-1B20N | D4E-2B20N | D4E-1B21N | D4E-2B21N |
Plunger | ![]() | D4E-1C[]0N | D4E-2C[]0N | D4E-1C20N | D4E-2C20N | D4E-1C21N | D4E-2C21N |
Sealed roller plunger | ![]() | D4E-1D[]0N | D4E-2D10N | D4E-1D20N | D4E-2D20N | D4E-1D21N | D4E-2D21N |
Sealed crossroller plunger | ![]() | D4E-1E[]0N | --- | D4E-1E20N | D4E-2E20N | D4E-1E21N | D4E-2E21N |
Sealed plunger | ![]() | D4E-1F[]0N | D4E-2F10N | D4E-1F20N | D4E-2F20N | D4E-1F21N | D4E-2F21N |
Roller lever | ![]() | D4E-1G[]0N | D4E-2G10N | D4E-1G20N | D4E-2G20N | D4E-1G21N | D4E-2G21N |
One-way action roller lever | ![]() | D4E-1H00N | --- | D4E-1H20N | D4E-2H20N | D4E-1H21N | --- |
For models with connectors, select one of the specified Cables with Connectors (sockets) from the following table.
Applicable limit switches | Current Type | Type | No. of conductors | Cable length | Model |
---|---|---|---|---|---|
D4E-[][]00N | AC | Straight![]() | 4 | 2 m | XS2F-A421-D90-F |
5 m | XS2F-A421-G90-F | ||||
D4E-[][]10N | DC | 2 m | XS2F-D421-D80-F | ||
5 m | XS2F-D421-G80-F |
last update: January 05, 2017
last update: November 06, 2012
Rated voltage | Standard load | Micro load | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Non-inductive load (A) | Inductive load (A) | Non-inductive load (A) | ||||||||
Resistive load | Lamp load | Inductive load | Motor load | Resistive load | ||||||
NC | NO | NC | NO | NC | NO | NC | NO | NC | NO | |
125 VAC 250 VAC | 5 (1) 5 (1) | 1.5 (1) 1.5 (1) | 3 (1) 3 (1) | 2 (1) 1 | 1 (1) 0.5 | 0.1 --- | ||||
8 VDC 14 VDC 30 VDC 125 VDC 250 VDC | 5 (1) 5 (1) 5 (1) 0.5 0.25 | --- --- --- --- --- | 1.5 (1) 1.5 (1) 1.5 (1) 0.05 0.03 | --- --- --- --- --- | 0.1 0.1 0.1 --- --- |
Minimum applicable load | Standard load | Micro load |
---|---|---|
160 mA at 5 VDC | 1 mA at 5 VDC |
Inrush current | NC | 10 A max. |
---|---|---|
NO | 10 A max. |
Note: 1. The above current ratings are for a standard current and the values in parentheses are for models with a
connector.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
Degree of protection | IP67 | |
---|---|---|
Durability * | Mechanical | 10,000,000 operations min. |
Electrical | 500,000 operations min. (5 A at 250 VAC, resistive load) 5,000,000 operations min. (10 mA at 24 VDC, resistive load) | |
Operating speed | 0.1 mm/sec to 0.5 m/sec | |
Operating frequency | Mechanical: 120 operations/min Electrical: 30 operations/min | |
Rated frequency | 50/60 Hz | |
Insulation resistance | 100 MΩ min. (at 500 VDC) | |
Contact resistance | 15 mΩ max. (initial value for the built-in switch when tested alone) | |
Dielectric strength | Between terminals of same polarity | 1,000 VAC, 50/60 Hz for 1 min |
Between each terminal and non-current-carrying metal part | 1,500 VAC, 50/60 Hz for 1 min/Uimp at 2.5 kV (EN60947-5-1) | |
Rated insulation voltage (Ui) | 250V | |
Pollution degree (operating environment) | 3 (EN60947-5-1) | |
Short-circuit protective device (SCPD) | 10 A fuse (type gG or gI, IEC60269 approved) | |
Conditional short-circuit current | 100 A (EN60947-5-1) | |
Conventional enclosed thermal current (Ithe) | 5 A (EN60947-5-1) | |
Protection against electric shock | Class II (grounding not required with double insulation) | |
Vibration resistance | Malfunction | 10 to 55 Hz, 1.5-mm double amplitude |
Shock resistance | Destruction | 1,000 m/s2 max. |
Malfunction | 300 m/s2 max. | |
Ambient operating temperature | -10°C to +80°C (with no icing) | |
Ambient operating humidity | 35% to 95%RH | |
Weight | Approx. 86 g (in case of roller plunger) |
last update: November 06, 2012