OMRON SHL Switches
last update: December 19, 2013
• Approved by EN, UL, CSA, and CCC (Chinese standard). (Ask your OMRON representative for information on approved models.)
• Incorporates a switch with a durable coil spring in a tough, highprecision case.
• Compact and uses a single basic switch for applications where strength is required.
• Models for microloads and models with operation indicators added to series.
• Terminal protective cover can be switched to wire cable from either the left or right.
• Sealing characteristics that meet IEC IP67 degree of protection.
last update: December 19, 2013
If you have just landed here, this product OMRON SHL Switches,Switches is offered online by Tianin FLD Technical Co.,Ltd. This is an online store providing Switches at wholesale prices for consumers. You can call us or send enquiry, we would give you the prices, packing,deliverty and more detailed information on the SHL We cooperate with DHL,TNT,FEDEX,UPS,EMS,etc.They guarantee to meet your needs in terms of time and money,even if you need your OMRON SHLSwitches tomorrow morning (aka overnight or next day air) on your desk, 2, 3 days or more.Note to international customers, YES, we ship worldwide.
FQ-M Series Vision Sensor/Features
ZFV-C Smart Sensors with Ultra-High-Speed Color CCD Cameras/Features
M22 Indicator (Cylindrical 22/25-dia.)/Features
G3PJ Solid State Relays for Heaters/Features
NX-ECS[][][] NX-series SSI Input Unit/Features
last update: September 24, 2012
Rated voltage | Non-inductive load (A) | Inductive load (A) | ||||||
---|---|---|---|---|---|---|---|---|
Resistive load | Lamp load | Inductive load | Motor load | |||||
NC | NO | NC | NO | NC | NO | NC | NO | |
125 VAC 250 VAC 480 VAC | 10 10 2 | 1.5 1.5 - | 3 2 - | 2.5 1.5 - | ||||
8 VDC 14 VDC 30 VDC 125 VDC 250 VDC | 10 10 5 0.4 0.2 | 2 2 1.5 0.4 0.2 | 5 5 1.5 0.05 0.03 | 2 2 1.5 0.05 0.05 |
Inrush current | NC | 15 A max. |
---|---|---|
NO | 15 A max. | |
Note:Note:
Note:The above figures are for steady-state currents.
Note:Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
Note:Lamp load has an inrush current of 10 times the steady-state current.
Note:Motor load has an inrush current of 6 times the steady-state current.
Rated voltage | Non-inductive load (A) | |
---|---|---|
Resistive load | ||
NC | NO | |
125 VAC | 0.1 | |
8 VDC 14 VDC 30 VDC | 0.1 0.1 0.1 |
Degree of protections | IP67 (EN60947-5-1) | |
---|---|---|
Durability | Mechanical | 10,000,000 operations min. |
Electrical | 500,000 operations min. | |
Operating speed | 0.1 mm/s to 0.5 m/s (hinge lever models) | |
Operating frequency | Mechanical | 120 operations/min |
Electrical | 30 operations/min | |
Rated frequency | 50/60 Hz | |
Insulation resistance | 100 MΩ min. (at 500 VDC) | |
Contact resistance | 15 mΩ max. (initial value for the built-in switch when tested alone) | |
Dielectric strength | Between terminals of the same polarity | 1,000 VAC, 50/60 Hz for 1 min |
Between each terminal and non- current-carrying metal part | 2,000 VAC, 50/60 Hz for 1 min/Uimp at 2.5 kV (EN60947-5-1) | |
Rated insulation voltage (Ui) | 150 V (EN60947-5-1) | |
Pollution degree (operating environment) | 3 (EN60947-5-1) | |
Short-circuit protective device (SCPD) | 10 A fuse type gI or gG (IEC60269) | |
Conditional short-circuit current | 100 A (EN60947-5-1) | |
Conventional enclosed thermal current (Ithe) | 5 A (EN60947-5-1) | |
Protection against electric shock | Class II (grounding not required with double insulation) | |
OFF reverse voltage | 1,000 VAC max., 300 VDC max. (EN60947-5-1) | |
Vibration resistance | Malfunction | 10 to 55 Hz, 1.5-mm double amplitude |
Shock resistance | Destruction | 1,000 m/s2 max. |
Malfunction | 300 m/s2 max. | |
Ambient operating temperature | -10°C to +80°C (with no icing) | |
Ambient operating humidity | 35% to 95%RH | |
Weight | Approx. 62 to 72 g |
Note:Note:
Note:The figures at the left are initial values.
Note:The ratings at the left may vary depending on the model. Contact your OMRON representative for further details.
Note:The head section of the plunger type SHL-D(Q)[][] is excluded.
Note:Durability values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH.
Note:The values are for the plunger-type models.
last update: September 24, 2012
last update: September 24, 2012
Type | Standard | Micro load | |
---|---|---|---|
Actuator | Model | Model | |
Plunger | ![]() | SHL-D55 | SHL-D55-01 |
Panel mount plunger | ![]() | SHL-Q55 | SHL-Q55-01 |
Panel mount roller plunger | ![]() | SHL-Q2255 | SHL-Q2255-01 |
Panel mount crossroller plunger | ![]() | SHL-Q2155 | SHL-Q2155-01 |
Short hinge lever | ![]() | SHL-W55 | SHL-W55-01 |
Hinge lever | ![]() | SHL-W155 | SHL-W155-01 |
Short hinge roller lever | ![]() | SHL-W255 | SHL-W255-01 |
Hinge roller lever | ![]() | SHL-W2155 | SHL-W2155-01 |
One-way action short hinge roller lever | ![]() | SHL-W355 | SHL-W355-01 |
One-way action hinge roller lever | ![]() | SHL-W3155 | SHL-W3155-01 |
Note:Models are also available with molded terminals and with molded terminals and operation indicators. Refer to Datasheet.
Standard | Micro load | ||
---|---|---|---|
Model | Model | Model | Model |
SHL-D55-MR SHL-Q55-MR SHL-Q2155-MR SHL-Q2255-MR SHL-W55-MR | SHL-W155-MR SHL-W255-MR SHL-W2155-MR SHL-W355-MR | SHL-D55-01MR SHL-Q55-01MR SHL-Q2155-01MR SHL-Q2255-01MR SHL-W55-01MR | SHL-W255-01MR SHL-W2155-01MR |
Standard | Micro load | |
---|---|---|
Model | Model | Model |
SHL-D55-ML SHL-Q2155-ML SHL-Q2255-ML SHL-W55-ML SHL-W155-ML | SHL-W255-ML SHL-W2155-ML | SHL-Q2255-01ML SHL-W2155-01ML |
Standard | Micro load | |
---|---|---|
Model | Model | Model |
SHL-D55-MD SHL-Q55-MD SHL-Q2155-MD SHL-Q2255-MD SHL-W55-MD | SHL-W155-MD SHL-W255-MD SHL-W2155-MD SHL-W355-MD | SHL-Q2255-01MD |
Standard | Micro load | |
---|---|---|
Model | Model | Model |
SHL-D55-LMR SHL-Q55-LMR SHL-Q2155-LMR SHL-Q2255-LMR SHL-W155-LMR SHL-W255-LMR SHL-W2155-LMR SHL-D55-L2MR SHL-Q2255-L2MR SHL-D55-L3MR SHL-Q55-L3MR SHL-Q2155-L3MR | SHL-Q2255-L3MR SHL-W155-L3MR SHL-W255-L3MR SHL-W2155-L3MR SHL-D55-L4MR SHL-Q55-L4MR SHL-Q2155-L4MR SHL-Q2255-L4MR SHL-W255-L4MR SHL-W2155-L4MR SHL-W355-L4MR | SHL-Q2255-01LMR SHL-W255-01LMR SHL-D55-01L3MR SHL-Q2155-01L3MR SHL-Q2255-01L3MR SHL-Q2155-01L4MR SHL-Q2255-01L4MR SHL-W255-01L4MR SHL-W2155-01L4MR |
Standard | Micro load | |
---|---|---|
Model | Model | Model |
SHL-Q55-LML SHL-Q2255-LML SHL-W155-LML SHL-W255-LML SHL-W2155-LML SHL-Q55-L2ML SHL-Q2255-L3ML | SHL-W55-L3ML SHL-W155-L3ML SHL-W255-L3ML SHL-Q2255-L4ML SHL-W155-L4ML | SHL-W255-01LML SHL-W2155-01LML SHL-Q2255-01L3ML SHL-W255-01L4ML |
Standard | Micro load | |
---|---|---|
Model | Model | Model |
SHL-Q2255-LMD SHL-W255-LMD SHL-Q55-L3MD | SHL-Q2255-L4MD SHL-W255-L4MD SHL-W2155-L4MD | SHL-Q55-01LMD SHL-Q2255-01L4MD |
last update: September 24, 2012
Catalog Name | Catalog Number [size] | Last Update | |
---|---|---|---|
![]() | - [865KB] | Nov 08, 201320131108 | SHL Data Sheet |
last update: September 24, 2012
Note:(Note: Omitted dimensions are the same as those of the plunger models.)
Note:Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
last update: September 24, 2012