OMRON H7BX Multifunction Counter (DIN 72 × 72)/Features Counters--OMRON H7BX Online Store

OMRON H7BXControl Components/ Counters/General-purpose

OMRON H7BX Control Components

OMRON H7BX Dimensions

/Images/l_1931-25-118930-198x198.jpg

• Highly visible display with backlit transmissive LCD.

• Selectable display color (red/green) enables checking output status at a distance.

• Easy operation with a key for each digit.

• Perform all basic settings with a DIP switch.

• Provides a total and preset counter, batch counter, dual counter, and tachometer (See note.).

• Wide range of inputs accepted for NPN/PNP inputs (multi-inputs) and 2-wire DC sensors.

• Complies with UL, CSA, and CE marking.

• Degree of protection: IP54 equivalent (front section only).

Note: The functions that can be selected depend on the model.

Purchase the OMRON General-purpose Please fill in the following

Title:

Email:

Tel:

Content:

Verification code:

If you have just landed here, this product OMRON H7BX Control Components,Control Components is offered online by Tianin FLD Technical Co.,Ltd. This is an online store providing Control Components at wholesale prices for consumers. You can call us or send enquiry, we would give you the prices, packing,deliverty and more detailed information on the H7BX We cooperate with DHL,TNT,FEDEX,UPS,EMS,etc.They guarantee to meet your needs in terms of time and money,even if you need your OMRON H7BXControl Components tomorrow morning (aka overnight or next day air) on your desk, 2, 3 days or more.Note to international customers, YES, we ship worldwide.

NB Series Programmable Terminals/Features
ZX1 Smart Sensor Laser Sensor with Built-in Amplifier/Features
E2EH Proximity Sensor Ideal for High Temperatures and Cleaning Processes/Features
E2K-F Flat Proximity Sensor/Features
CRT1-[]D08(-1) / []D16(-1) / ROS[] / ROF[] Digital I/O Slave Units with Screw Terminal Blocks (2-...


OMRON H7BX catalog

H7BX Multifunction Counter (DIN 72 × 72)/Catalog

  • Catalog
  • Manual
  • CAD

English

Global Edition

For ordering in Singapore, please note some product models not sold in Singapore may be included in the following catalog(s) for our global customers.

*It is recommended to select “Save” from the right-click due to large size of catalog PDF data.

Catalog Name Catalog Number
[size]
Last Update
H7BX Data Sheet -
[4265KB]
Jun 15, 201820180615 H7BX Data Sheet


OMRON H7BX dimension

H7BX Multifunction Counter (DIN 72 × 72)/Dimensions

Counter

Counter
H7BX-A[][]

H7BX Dimensions 2

Note: M3.5 terminal screws (effective length: 6 mm).

Dimensions with Flush Mounting Adapter
H7BX-A[][]

(The flush mounting adapter is supplied with the H7BX.)

H7BX Dimensions 3

Panel Cutouts

Panel cutouts are as shown below(according to DIN 43700).

H7BX Dimensions 5

Note: The mounting panel thickness must be 1 to 5 mm.


OMRON H7BX lineup

H7BX Multifunction Counter (DIN 72 × 72)/Lineup

External power supplyOutput typeSupply voltage1-stage2-stage
12 VDCContact and
NPN transistor output
100 to 240 VACH7BX-AH7BX-AW
24 VAC/12 to 24 VDCH7BX-AD1H7BX-AWD1

Accessories (Order Separately)

NameModel
Soft CoverY92A-72F1
Hard CoverY92A-72
Terminal Cover *Y92A-72T

* Supplied with the H7BX.


OMRON H7BX specification

H7BX Multifunction Counter (DIN 72 × 72)/Specifications

Ratings

ModelH7BX-A/AD1H7BX-AW/AWD1
TypePreset counterPreset counter/tachometer
Supported configurations1-stage preset counter, total and
preset counter *1 (selectable)
1-stage preset counter, 2-stage preset
counter, total and preset counter (*1),
batch counter, dual counter, tachometer
(selectable)
RatingsPower supply voltage
*2
H7BX-A/AW: 100 to 240 VAC (50/60 Hz)
H7BX-AD1/AWD1: 24 VAC (50/60 Hz)/12 to 24 VDC (ripple 20% max.)
Operating voltage
range
85% to 110% of rated supply voltage (90% to 110% at 12 VDC)
Power consumptionH7BX-A/AW: 9.6 VA max. (100 to 240 VAC)
H7BX-AD1/AWD1: 8 VA max. (24 VAC), 5.3 W max. (12 to 24 VDC)
Mounting methodFlush mounting
External connectionsScrew terminals
Degree of protectionIP54 (front section only)
Input signalsCP1, CP2, reset 1, reset 2, key protection
CounterMax. counting speed30 Hz or 5 kHz (selectable, ON/OFF ratio 1:1), setting for both CP1 and CP2
Input modesIncrement, decrement, command (UP/DOWN A), individual (UP/DOWN B),
quadrature (UP/DOWN C)
Output modesN, F, C, R, K-1, P, Q, A, K-2, D, LN, F, C, R, K-1, P, Q, A, K-2, D, L, H
One-shot output time0.01 to 99.99 s
Reset inputExternal reset (minimum reset input signal width: 1 ms or 20 ms selectable),
manual reset, and automatic reset (internal according to C, R, P, and Q mode
operation)
TachometerPulse measurement
method
---Periodic measurement (Sampling period:
200 ms)
Max. counting speed---30 Hz or 10 kHz (selectable)
Measuring ranges---30 Hz: 0.01 to 30.00 Hz
10 kHz: 0.01 Hz to 10 kHz
Measuring accuracy---±0.1% FS ±1 digit max. (at 23 ±5°C)
Output modes---Upper and lower limits, area, upper limit,
lower limit
Auto-zero time---0.1 to 99.9 s
Startup time---0.0 to 99.9 s
Average processing---OFF/2/4/8 times
Prescaling functionYes (0.001 to 99.999)
Decimal point adjustmentYes (rightmost 3 digits)
Sensor waiting time290 ms max. (Control output is turned OFF and no input is accepted during
sensor waiting time.)
Key protection inputResponse speed: Approx. 1 s
No-voltage NPN input (fixed)
Short-circuit (ON) impedance: 1 kΩ max. (Leakage current at 0 Ω: Approx.
12 mA)
Short-circuit (ON) residual voltage: 3 V max.
Open (OFF) impedance: 100 kΩ min.
Input method
(except key protection input)
No-voltage NPN input or voltage PNP input (selectable)
No-voltage input
Short-circuit (ON) impedance: 1 kΩ max. (Leakage current at 0 Ω: Approx.
12 mA)
Short-circuit (ON) residual voltage: 3 V max.
Open (OFF) impedance: 100 kΩ min.
Voltage input
High level: 4.5 to 30 VDC
Low level: 0 to 2 VDC
Input resistance: Approx. 4.7 kΩ
External power supply12 VDC (±10%), 100 mA (For details, refer to External Power Supply on Data
Sheet.)
Control outputContact output: 3 A at 250 VDC/30 VDC, resistive load (cosφ = 1)
Minimum applied load: 10 mA at 5 VDC (Failure level: P, reference value)
Transistor output: 100 mA max. at 30 VDC max.
Residual voltage: 1.5 VDC max. (approx. 1 V)
Leakage current: 0.1 mA max.
Display *3Backlit 7-segment negative transmissive LCD
Character Heights
PV: 13.5 mm (red/green)
SV: 9 mm (green)
Digits6 digits
-99,999 to 999,999 (5 digits
negative and 6 digits positive)
6 digits
Counter: -99,999 to 999,999 (5 digits
negative and 6 digits positive)
Tachometer: 0 to 999,999 (6 digits)
Memory backupEEPROM (Overwrites: 100,000 min.), Data storage: 10 years min.
Ambient operating temperature-10 to 55°C (with no icing)
Ambient storage temperature-25 to 65°C (with no icing)
Ambient operating humidity25 to 85°C (with no condensation)
Case colorBlack (N1.5)
AccessoriesTwo flush-mounting adapters,
terminal cover
Two flush-mounting adapters, terminal
cover, DIP switch setting stickers

*1. The total and preset counter functions as a 1-stage preset counter and total counter.
*2. Do not use an inverter output for the power supply.
*3. Displayed only when the power is ON. Not displayed when the power is OFF.

Characteristics

Insulation resistance100 MΩ min. (at 500 VDC) between current-carrying terminal and exposed
non-current-carrying metal parts, and between non-continuous contacts
Dielectric strengthBetween current-carrying metal parts and non-current-carrying metal parts:
2,000 VAC, 50/60 Hz for 1 min
Between power supply and input circuit: 2,000 VAC, 50/60 Hz for 1 min
(for models other than the H7BX-A[]D1)
1,000 VAC, 50/60 Hz for 1 min (H7BX-A[]D1)
Between control output, power supply, and input circuit: 2,000 VAC, 50/60 Hz for 1 min
Between non-continuous contacts: 1,000 VAC, 50/60 Hz for 1 min
Impulse withstand voltageBetween power terminals: 3.0 kV (1.0 kV for 24 VAC/12 to 24 VDC models)
Between current-carrying terminal and exposed non-current-carrying metal parts:
4.5 kV (1.5 kV for 24 VAC/12 to 24 VDC models)
Noise immunityBetween power terminals: ±1.5 kV
Between input terminals: ±600 V
Square-wave noise by noise simulator (Pulse width: 100 ns/1 μs, 1-ns rise)
Static immunityMalfunction: 8 kV
Destruction: 15 kV
Vibration resistanceDestruction: 10 to 55 Hz, 0.75-mm single amplitude, 2 hours each in three directions
Malfunction: 10 to 55 Hz, 0.50-mm single amplitude, 10 minutes each in three directions
Shock resistanceDestruction: 294 m/s2 3 times each in 6 directions
Malfunction: 98 m/s2 3 times each in 6 direction
Life expectancyMechanical: 10,000,000 operations min.
Electrical: 100,000 operations min. (3 A at 250 VAC/30 VDC, resistive load) *
WeightApprox. 250 g

* Check the electrical life expectancy curve.

Electrical Life Expectancy (Reference Values)

Resistive Load

H7BX Specifications 6

Inductive Load

H7BX Specifications 7

A current of 0.15 A max. can be switched at 125 VDC (cosφ = 1) and current of 0.1 A max. can be switched with L/R = 7 m/s. In both cases, a life of 100,000 operations can be expected.

Applicable Standards

Approved
safety
standards
cURus: UL 508, CSA C22.2 No. 14
EN 61010-1 (IEC 61010-1): Pollution degree 2/overvoltage category II;
EN 61326; VDE 0106 Part 100
EMC(EMI) EN 61326-1 *
Emission Enclosure: EN 55011 Group 1 class A
Emission AC mains: EN 55011 Group 1 class A
(EMS) EN 61326-1 *
Immunity ESD: EN 61000-4-2: 4 kV contact discharge; 8 kV air discharge
Immunity RF-interference: EN 61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz); 10 V/m (Pulse-
modulated, 900 MHz ±5 MHz)
Immunity Conducted Disturbance: EN 61000-4-6: 3 V (0.15 to 80 MHz)
Immunity Burst: EN 61000-4-4: 2 kV power-line; 1 kV I/O signal-line
Immunity Surge: EN 61000-4-5: 1 kV line to lines (power and output lines (relay outputs)); 2 kV line to
ground (power and output lines (relay outputs))
Immunity Voltage Dip/Interruption: EN 61000-4-11: 0.5 cycle, 100% (rated voltage)

* Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)

I/O Functions

Using as a Counter *1

InputsCP1, CP2(1) All Modes Except for Dual Counter Mode
Reads count signals.
Increment, decrement, up/down (command, individual, or quadrature) inputs can be used.
(2) Dual Counter Mode
Reads CP1 count signals on CP1 input and CP2 count signals on CP2 input.
Increment signals can be used.
Reset or
Reset 1
(1) All Modes Except for Dual Counter Mode
Resets present value and outputs (OUT2 when using the batch counter). *2
Counting cannot be performed while resetting or when reset 1 input is ON.
The reset indicator is lit while the reset input is ON.
(2) Dual Counter Mode
Resets the CP1 present value to 0.
Counting the CP1 input cannot be performed while the reset 1 input is ON.
The reset indicator is lit while the reset 1 input is ON.
Total Reset
or Reset 2
The reset operation depends on the selected function. *3
OutputsOUT1, 2When the corresponding set value is reached, signals are output according to the designated output mode.

*1. Refer to Data Sheet for information on the operation of input and output functions.
*2. In increment mode or increment/decrement mode, the present value returns to 0; in decrement mode, the present
       value returns to the set value with 1-stage models, and returns to set value 2 with 2-stage models.
*3. The reset indicator will not be lit when the total reset or reset 2 input is ON.

FunctionReset operation
1-stage/2-stage preset counterDoes not operate (Not used).
Total and preset counterResets the total count value.
Holds the total count value at 0 while the total reset input is ON.
Batch counterResets the batch count value and batch output (OUT1).
Holds the batch count value at 0 while the reset 2 input is ON.
Dual counterResets the CP2 present value.
Counting for CP2 input is disabled while the reset 2 input is ON.

Using as a Tachometer

InputsCP1, CP2Reads counting signals. (CP2 input is not available.)
Reset 1,
Reset 2
Holds the measurement value and outputs. (Reset 2 input is not available.)
The reset indicator is lit during hold.
OutputsOUT1, 2Outputs signals according to the specified output mode when a set value is reached.

Using as a Counter or Tachometer

Key protection inputProhibits using the keys on the front panel.
Set the key protection level in function selection mode.
Key protection is enable by short-circuited key protection terminals.

Note: For details, refer to Data Sheet.


Return to OMRON