OMRON ZC-[]55 Switches
last update: December 19, 2013
• Small, High-precision Enclosed Switches with Built-in Basic Switches for High Repeatability and Durability of 10 Million Operations Minimum.
• Same mounting pitch as Z Basic Switch.
• Requires less operating force than conventional limit switches.
• Lineup includes modes with operation indicators for easy maintenance and inspection.
• Approved by EN, UL, CSA, and CCC (Chinese standard). (Ask your OMRON representative for Information on approved models.)
last update: December 19, 2013
If you have just landed here, this product OMRON ZC-[]55 Switches,Switches is offered online by Tianin FLD Technical Co.,Ltd. This is an online store providing Switches at wholesale prices for consumers. You can call us or send enquiry, we would give you the prices, packing,deliverty and more detailed information on the ZC-[]55 We cooperate with DHL,TNT,FEDEX,UPS,EMS,etc.They guarantee to meet your needs in terms of time and money,even if you need your OMRON ZC-[]55Switches tomorrow morning (aka overnight or next day air) on your desk, 2, 3 days or more.Note to international customers, YES, we ship worldwide.
V400-H Handheld 2D Code Reader/Features
G7S-[]-E Relays with Forcibly Guided Contacts/Features
M2BJ Buzzer (Cylindrical 16-dia.)/Features
NJ-PA / PD NJ-Series Power Supply Unit/Features
S8VK-C Switch Mode Power Supply (60/120/240/480-W Models)/Features
Catalog Name | Catalog Number [size] | Last Update | |
---|---|---|---|
![]() | - [605KB] | Aug 29, 201220120829 | ZC-[]55 Data Sheet |
last update: September 24, 2012
Rated voltage | Non-inductive load (A) | Inductive load (A) | ||||||
---|---|---|---|---|---|---|---|---|
Resistive load | Lamp load | Inductive load | Motor load | |||||
NC | NO | NC | NO | NC | NO | NC | NO | |
125 VAC 250 VAC | 10 10 | 3 2.5 | 1.5 1.25 | 10 10 | 5 3 | 2.5 1.5 | ||
8 VDC 14 VDC 30 VDC 125 VDC 250 VDC | 10 10 6 0.5 0.25 | 3 3 3 0.4 0.2 | 1.5 1.5 1.5 0.4 0.2 | 6 6 5 0.05 0.03 | 5 5 5 0.05 0.03 | 2.5 2.5 2.5 0.05 0.03 |
Inrush current | NC | 30 A max. |
---|---|---|
NO | 15 A max. |
Note:Note:
Note:The above figures are for steady-state currents.
Note:Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
Note:Lamp load has an inrush current of 10 times the steady-state current.
Note:Motor load has an inrush current of 6 times the steady-state current.
Note:The above ratings were tested under the following conditions according.
(1) Ambient temperature:+20±2°C
(2) Ambient humidity: 65±5%RH
(3) Operating frequency:20 operations/min.
Degree of protections | IP67 | |
---|---|---|
Durability | Mechanical | 10,000,000 operations min. |
Electrical | 500,000 operations min. | |
Operating speed | 0.05 mm/s to 0.5 m/s *1 | |
Operating frequency | Mechanical | 120 operations/min |
Electrical | 20 operations/min | |
Insulation resistance | 100 MΩ min. (at 500 VDC) | |
Contact resistance | 15 mΩ max. (initial value for the builtin switch when tested alone) | |
Dielectric strength | Between non-continuous terminals | 1,000 VAC, 50/60 Hz for 1 min |
Between each terminal and non- current-carrying metal parts | 2,000 VAC, 50/60 Hz for 1 min | |
Rated insulation voltage (Ui) | 1,000 VAC | |
Pollution degree (operating environment) | 3 (IEC947-5-1) | |
Short-circuit protective device | 10 A-fuse type gG (IEC 60269) | |
Protection against electric shock | Class II | |
Proof tracking index (PTI) | 175 | |
Switch category | D (IEC335) | |
Rated operating current (Ie) | 10 A | |
Rated operating voltage (Ue) | 250 VAC | |
Vibration resistance | Malfunction | 10 to 55 Hz, 1.5-mm double amplitude *2 |
Shock resistance | Destruction | 1,000 m/s2 max. |
Malfunction | 300 m/s2 max. (in case of plunger model) *1 *2 | |
Ambient operating temperature | -10°C to +80°C (with no icing) | |
Ambient operating humidity | 35% to 95%RH | |
Weight | Approx. 92 g (in case of ZC-Q22(21)55) |
Note:Only for models with plungers. (Contact your OMRON representative for information on other models.)
Note:Less than 1 ms under a free state at the operating limits.
last update: September 24, 2012
last update: September 24, 2012
Note:Note:
1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. Operating characteristics are for when the Switch is operated from direction A.
last update: September 24, 2012
last update: September 24, 2012
Actuator | Model | Approved Standards | |||
---|---|---|---|---|---|
UL | CSA | EN | |||
Plunger | ![]() | ZC-D55 | ● | ● | ● |
Panel mount plunger | ![]() | ZC-Q55 | ● | ● | ● |
Panel mount roller plunger | ![]() | ZC-Q2255 | ● | ● | ● |
Panel mount crossroller plunger | ![]() | ZC-Q2155 | ● | ● | ● |
Sealed roller plunger | ![]() | ZC-N2255 | ● | ● | ● |
Sealed crossroller plunger | ![]() | ZC-N2155 | ● | ● | ● |
Short hinge lever | ![]() | ZC-W55 | ● | ● | ● |
Hinge lever | ![]() | ZC-W155 | ● | ● | ● |
Short hinge roller lever | ![]() | ZC-W255 | ● | ● | ● |
Hinge roller lever | ![]() | ZC-W2155 | ● | ● | ● |
One-way action short hinge roller lever | ![]() | ZC-W355 | ● | ● | ● |
One-way action hinge roller lever | ![]() | ZC-W3155 | ● | ● | ● |
Note:Note:
1. Use molded terminal models when using the Switch under one of the following conditions:a) dusty, b) high amount of dripping oil, or c) high humidity.
2. Models are available with lead outlets in three positions: right-hand, left-hand, and underside.
last update: September 24, 2012