OMRON WS02-SGWC1 / CPLC1 Automation Systems
last update: February 1, 2018
The need for faster transmission of more and more information between personal computers and PLCs is coupled with the need for frequent changes to specifications, such as address allocations in PLCs, a demand for software standardization to eliminate dependence on specific applications and networks, and a demand for cost reductions.
OMRON provides the functions to solve these problems. Data links are now possible using Ethernet. Data links can even be accessed via a LAN port on a notebook computer. And FA Communications Software can be used to access PLC data by using only tag names to enable more flexible and higher-speed access of PLC data from personal computers, and that lowers costs by eliminating the need for a special board for data links.
* This software runs on WOW64 (Windows-On-Windows 64). Customer application must be run as 32bit process.
CX-Compolet software enables easily reading and writing PLC data using Visual Basic and C#. It is the successor to SYSMAC Compolet.
SYSMAC Gateway can be used as the communications driver on most networks. It is the successor to FinsGateway and has inherited all FinsGateway functionality.
Sysmac is a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products.
Microsoft, Visual Basic, Visual Studio, ActiveX and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.
Microsoft product screen shots reprinted with permission from Microsoft Corporation.
iPhone and iPad are registered trademarks of Apple Inc.
Other company names and product names in this document are the trademarks or registered trademarks of their respective companies.
Application data can be accessed using tag names rather than addresses.
Data links are possible between personal computers and PLCs on Ethernet/IP networks.
Note: The Network Configurator included in the CX-One Package or Sysmac Studio is required to set tag data links.
Tag access is available with CJ2-series and NJ/NX-series CPU Units, NY-series Industrial PC with EtherNet/IP
functionality.
But, the tag data link with internal port of NY series is impossible.
* NY-series is only Industrial PC Platform NY-series IPC Machine Controller.
last update: February 1, 2018
If you have just landed here, this product OMRON WS02-SGWC1 / CPLC1 Automation Systems,Automation Systems is offered online by Tianin FLD Technical Co.,Ltd. This is an online store providing Automation Systems at wholesale prices for consumers. You can call us or send enquiry, we would give you the prices, packing,deliverty and more detailed information on the WS02-SGWC1 / CPLC1 We cooperate with DHL,TNT,FEDEX,UPS,EMS,etc.They guarantee to meet your needs in terms of time and money,even if you need your OMRON WS02-SGWC1 / CPLC1Automation Systems tomorrow morning (aka overnight or next day air) on your desk, 2, 3 days or more.Note to international customers, YES, we ship worldwide.
FQ-CR Series Code Reader/Features
EE-SPX-W Slot-type Photomicrosensor with Cable/Features
A22 Pushbutton Switch (Cylindrical 22/25-dia.)/Features
G9SX-LM Low-speed Monitoring Unit/Features
CPM2C-S1[]0C-DRT Programmable Slaves/Features
last update: September 3, 2018
Product name | Specification | Model | Standards |
---|---|---|---|
CX- Compolet * | Software components that can make it easy to create programs for communications between a computer and controllers. This packaged product bundles CX-Compolet and SYSMAC Gateway with 1 license each. Supported execution environment: .NET Framework (2.0, 3.0, 3.5, 4.0 or 4.5.1) Development environment: Visual Studio 2005/2008/2010/2012/2013/2015/2017 Development languages: Visual Basic, C# Supported communications: Equal to SYSMAC Gateway. | WS02-CPLC1 | --- |
3 additional licenses (This product provides only additional licenses. The software must be purchased in advance.) | WS02-CPLC1-L3 | ||
5 additional licenses (This product provides only additional licenses. The software must be purchased in advance.) | WS02-CPLC1-L5 | ||
10 additional licenses (This product provides only additional licenses. The software must be purchased in advance.) | WS02-CPLC1-L10 | ||
Software components only. This package includes CX-Compolet with 1 license. SYSMAC Gateway is not included. | WS02-CPLC2 |
* One license is required per computer (execution environment).
Note 1: When .NET Framework version1.1 (Visual Studio 2003) is used for develoment, only the specifications of
CX-Compolet version 1.5 are available.
Product name | Specification | Model | Standards |
---|---|---|---|
SYSMAC Gateway *1 | Communications middleware for personal computers running Windows. Supports CIP communications and tag data links (EtherNet/IP) in addition to FinsGateway functions. This package includes SYSMAC Gateway with 1 licence. (Fins Gateway is also included.) Supported communications: RS-232C, USB, Controller Link, SYSMAC LINK, Ethernet, EtherNet/IP | WS02-SGWC1 | --- |
10 additional licenses (This product provides only additional licenses.) | WS02-SGWC1-L10 | ||
SYSMAC Gateway SDK *2 | Software development kit for creating communications programs using SYSMAC Gateway. Development languages: C, C++ Please contact your OMRON sales representative when purchasing SYSMAC Gateway. | WS02-SGWC1S |
*1. One license is required per computer (execution environment).
*2. SYSMAC Gateway SDK doesn't include the license of SYSMAC Gateway.
Please purchase SYSMAC Gateway when execution environment is required.
last update: September 3, 2018
last update: September 24, 2012
No information is provided on the dimensions of this product.
last update: September 24, 2012
Catalog Name | Catalog Number [size] | Last Update | |
---|---|---|---|
![]() | V302-E1-12 [1312KB] | Oct 01, 201820181001 | CX-Compolet, SYSMAC Gateway Catalog |
last update: October 1, 2018
Item | Requirement | |
---|---|---|
Operating system (OS) Japanese or English system | Microsoft Windows Server 2003 (32bit) Microsoft Windows XP SP3 (32bit) Microsoft Windows Vista (32bit) | Microsoft Windows Server 2008(32bit/64bit*) Microsoft Windows Server 2008 R2(64bit*) Microsoft Windows Server 2012(64bit*) Microsoft Windows Server 2012 R2(64bit*) Microsoft Windows Server 2016(64bit*) Microsoft Windows 7(32bit/64bit*) Microsoft Windows 8(32bit/64bit*) Microsoft Windows 8.1(32bit/64bit*) Microsoft Windows 10(32bit/64bit*) |
Personal compute | Windows computers with Intel x86 processor | Windows computers with Intel 32bit (x86) processor or 64bit (x64) -based processor |
Hard disk | At least 400 MB of available space |
* This software runs on WOW64 (Windows-On-Windows 64). Customer application must be run as 32bit process.
Note 1: USB Port on the PC can not be shared between SYSMAC Gateway and CX-One in Windows Vista or higher.
Note 2: System requirements for Windows computers are the same as those recommended by Microsoft.
Note 3: The compatible functions of SYSMAC Compolet V2 are supported by Windows XP only.
Yes: Supported, No: Not Supported
Communications Method | Protocols | Specifying memory areas | SYSMAC Gateway SDK (WS02-SGWC1S) | CX-Compolet+SYSMAC Gateway (WS02-CPLC1) |
---|---|---|---|---|
Message Communications | FINS | Physical address | Yes | Yes |
CIP | Physical address | Yes *1 | Yes | |
Tag names | No | Yes | ||
Tag Data Links (EtherNet/IP) | CIP | Physical address | Yes *2 | Yes |
Tag names | No | Yes | ||
Development languages | C, C++ | Visual Basic, C# |
*1 Please use after understanding the CIP Communications Specifications.
*2 Data is transferred through the event memory.
Yes: Supported, No: Not Supported
Personal computer | RS-232C | ||||
---|---|---|---|---|---|
PLC | SYSWAY (Host Link C Mode) | SYSWAY-CV (Host Link FINS) | CompoWay/F (master at personal computer) | Peripheral Bus | |
NX7/NJ1 (unit version 1.10 or later)*1 NJ5/NJ3 (unit version 1.03 or later)*2 NX1(unit version 1.30 or later)*3 NX1P (unit version 1.13 or later)*4 NY5[][]-1 (unit version 1.12 or later)*4 | No | No | No | No | |
CJ2 with EtherNet/IP functionality | Yes | Yes | No | Yes (Peripheral Bus - CS/CJ) | |
CJ1 | Yes | Yes | No | Yes (Peripheral Bus - CS/CJ) | |
CS1 | Yes | Yes | No | Yes (Peripheral Bus - CS/CJ) | |
CP1 | Yes *8 | Yes *8 | No | Yes *8 (Peripheral Bus - CS/CJ) | |
C Series | C200HX/HG/HE, CQM1H | Yes | No | No | Yes (Peripheral Bus - C) |
CPM1/CPM2 | Yes | No | No | Yes (Peripheral Bus - C) | |
CVM1/CV | Yes | Yes | No | Yes (Peripheral Bus - CV) | |
CompoWay/F Slaves, such as Temperature Controllers | No | No | Yes | No |
Personal computer | USB | Ethernet (LAN) | Controller Link | ||
---|---|---|---|---|---|
PLC | FINS | Ethernet (FINS) | EtherNet/IP | FINS | |
NX7/NJ1 (unit version 1.10 or later)*1 NJ5/NJ3 (unit version 1.03 or later)*2 NX1(unit version 1.30 or later)*3 NX1P (unit version 1.13 or later)*4 NY5[][]-1 (unit version 1.12 or later)*4 | No | No | Yes *5 | No | |
CJ2 with EtherNet/IP functionality | Yes | Yes | Yes (Specification using tag names is possible.) | Yes *6 | |
CJ1 | No | Yes *6 (Communications Units are not required for CJ1M PLCs with Ethernet functionality.) | Yes *6, *7 | Yes *6 | |
CS1 | No | Yes *6 | Yes *6, *7 | Yes *6 | |
CP1 | Yes | Yes *9 | No | Yes *6 (CP1H only) | |
C Series | C200HX/HG/HE, CQM1H | No | No | No | Yes *6 |
CPM1/CPM2 | No | No | No | No | |
CVM1/CV | No | Yes *6 | No | Yes *6 | |
CompoWay/F Slaves, such as Temperature Controllers | No | No | No | No |
Note: Including models whose production were discontinued.
*1. To connect the NX7/NJ1 Controller, CX-Compolet / SYSMAC Gateway version 1.70 or higher is required.
*2. To connect the NJ3/5 Controller, CX-Compolet / SYSMAC Gateway version 1.31 or higher is required.
*3. To connect the NX1 Controller, CX-Compolet / SYSMAC Gateway version 1.72 or higher is required.
*4. To connect the NX1P/NY5[][]-1 Controller, CX-Compolet / SYSMAC Gateway version 1.71 or higer is required.
*5. Tag data links between SYSMAC Gateway and the NJ/NX-series CPU Unit or Industrial PC Platform NY-series IPC Machine Controller can be created within the CJ-series specifications for variable with basic data type, array variable, and structure variable. SYSMAC Gateway memory allocation of structure variable is the same as the CJ-series.
But, the tag data link with internal port of NY series is impossible.
*6. A separate Communications Unit is required.
*7. Specification using tag names is not possible.
*8. It cannot be used for CP1E E-type.
*9. The CP1W-CIF41 is required for the CP1H / CP1L other than CP1L-EM/EL. The CP1W-CIF41 version 2.0 or later is required for the CP1E N-type.
It cannot be used for CP1E E-type.
Supported CX-Compolet/SYSMAC Gateway | |||
---|---|---|---|
Supported OS | Client | Windows XP (32bit) | Ver.1.00 or higher |
Windows Vista (32bit) | Ver.1.00 or higher | ||
Windows 7 (32bit) | Ver.1.10 or higher | ||
Windows 7 (64bit) | Ver.1.20 or higher | ||
Windows 8 (32bit/64bit) | Ver.1.50 or higher | ||
Windows 8.1 (32bit/64bit) | Ver.1.40 or higher | ||
Windows 10 (32bit/64bit) | Ver.1.70 or higher | ||
Server | Windows Server 2003 (32bit) | Ver.1.10 or higher | |
Windows Server 2008 (32bit) | Ver.1.10 or higher | ||
Windows Server 2008/R2 (64bit) | Ver.1.20 or higher | ||
Windows Server 2012/R2 (64bit) | Ver.1.50 or higher | ||
Windows Server 2016 (64bit) | Ver.1.72 or higher | ||
Development environment | Visual Studio 2005 | Ver.1.00 or higher | |
Visual Studio 2008 | Ver.1.00 or higher | ||
Visual Studio 2010 | Ver.1.10 or higher | ||
Visual Studio 2012 | Ver.1.50 or higher | ||
Visual Studio 2013 | Ver.1.40 or higher | ||
Visual Studio 2015 | Ver.1.70 or higher | ||
Visual Studio 2017 | Ver.1.72 or higher |
Note 1: From SYSMAC Gateway version 1.60, the unit revision has been changed to revision 3. When EtherNet/IP tag
data links are set for SYSMAC Gateway unit revision 1 (SYSMAC Gateway version 1.2 or lower) or revision 2
(SYSMAC Gateway version 1.3 to 1.5), the settings need to be changed to revision 3 with Network Configurator
for EtherNet/IP.
2: When EtherNet/IP tag data links are set to use SYSMAC Gateway unit revision 3 (version 1.60 or higher) as a
node, Network Configurator for EtherNet/IP version 3.57 or higher is required. (Network Configurator for
EtherNet/IP is included in
· CX-Compolet WS02-CPLC1 version 1.60 or higher
· SYSMAC Gateway WS02-SGWC1 version 1.60 or higher
· Sysmac Studio version 1.12 or higher
· CX-One version 4.33 and CX-One auto update (November 2014 or later)
3: If you need to upgrade to the latest version of CX-Compolet, consult you OMRON representative.
Ethernet | RS- 232C | USB | Controller Link | SYSMAC LINK | |||||
---|---|---|---|---|---|---|---|---|---|
Ethernet (FINS) | EtherNet/IP | PCI | ISA | ||||||
Sup- ported OS | Client | Windows XP (32bit) | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Windows Vista (32bit) | Yes | Yes | Yes | Yes | Yes | Yes | Yes | ||
Windows 7 (32bit) | Yes | Yes | Yes | Yes | Yes | No | No | ||
Windows 7 (64bit) | No | ||||||||
Windows 8 (32bit/64bit) | Yes | Yes | Yes | Yes | No | No | No | ||
Windows 8.1 (32bit/64bit) | Yes | Yes | Yes | Yes | No | No | No | ||
Windows 10 (32bit/64bit) | Yes | Yes | Yes | Yes | No | No | No | ||
Server | Windows Server 2003 (32bit) | Yes | Yes | Yes | Yes | Yes | Yes | Yes | |
Windows Server 2008 (32bit) | Yes | Yes | Yes | Yes | Yes | No | No | ||
Windows Server 2008/R2 (64bit) | No | ||||||||
Windows Server 2012/R2 (64bit) | Yes | Yes | Yes | Yes | No | No | No | ||
Windows Server 2016 (64bit) | Yes | Yes | Yes | Yes | No | No | No |
last update: October 1, 2018