OMRON G3H / G3HD Relays
last update: December 19, 2013
• Certified by UL, CSA, and VDE (models numbers with a suffix of “-VD”).
• Socket type, same size as LY Power Relays.
• Operation indicator provided to confirm input (models numbers with “N” before the suffix).
last update: December 19, 2013
If you have just landed here, this product OMRON G3H / G3HD Relays,Relays is offered online by Tianin FLD Technical Co.,Ltd. This is an online store providing Relays at wholesale prices for consumers. You can call us or send enquiry, we would give you the prices, packing,deliverty and more detailed information on the G3H / G3HD We cooperate with DHL,TNT,FEDEX,UPS,EMS,etc.They guarantee to meet your needs in terms of time and money,even if you need your OMRON G3H / G3HDRelays tomorrow morning (aka overnight or next day air) on your desk, 2, 3 days or more.Note to international customers, YES, we ship worldwide.
V430-F Series Auto Focus Multi Code Reader/Features
WL, WLM Two-circuit Limit Switch/Long-life Two-circuit Limit Switch/Features
H7CX-A Multifunction Preset Counter/Features
GX-ID16[]2 / OD16[]2 / MD16[]2 Digital I/O Terminal 3-tier Terminal Block Type/Features
SmartController EX Robot Controllers/Features
Catalog Name | Catalog Number [size] | Last Update | |
---|---|---|---|
![]() | - [465KB] | Oct 02, 201720171002 | G3H, G3HD Data Sheet |
last update: November 06, 2012
last update: November 06, 2012
last update: October 2, 2017
Isolation | Zero cross function | Indicator | Rated output load | Rated input voltage | Model |
---|---|---|---|---|---|
Photocoupler | Yes | Yes | 3 A at 100 to 240 VAC *1 | 5 to 24 VDC | G3H-203SN-VD |
Phototriac coupler | No | 5 VDC | G3H-203SLN-VD | ||
12 VDC | |||||
24 VDC | |||||
Photocoupler | --- | 3 A at 4 to 48 VDC *2 | 5 to 24 VDC | G3HD-X03SN-VD | |
Photocoupler | Yes | No | 3 A at 100 to 240 VAC *1 | 4 to 24 VDC | G3H-203S-VD |
Phototriac coupler | No | 5 VDC | G3H-203SL-VD | ||
12 VDC | |||||
24 VDC | |||||
Photocoupler | --- | 3 A at 4 to 48 VDC *2 | 4 to 24 VDC | G3HD-X03S-VD | |
Photovoltaic coupler | --- | Yes | 2.5 A at 24 to 240 VDC *3 *4 | 12 to 24 VDC | G3HD-202SN-VD |
*1 Product is labelled "240 VAC".
*2 Product is labelled "48 VDC".
*3 Product is labelled "240 VDC".
*4 Application is possible for a half-wave rectification load between 19.2 and 264 VAC.
Front-mounting Sockets | Back-mounting Sockets | |||
---|---|---|---|---|
Socket | PTF08A(-E) | PT08 | PT08-0 | PT08QN |
Hold-down Clip | PYC-A1 | PYC-P PYC-S | PYC-P | PYC-P PYC-S |
last update: October 2, 2017
last update: November 06, 2012
Model | Rated voltage | Operating voltage | Impedance | Voltage level | |
---|---|---|---|---|---|
Must operate voltage | Must release voltage | ||||
G3H-203SN-VD | 5 to 24 VDC | 4 to 28 VDC | 15 mA max. (See note 2.) | 4 VDC max. | 1 VDC min. |
G3H-203SLN-VD | 5 VDC | 4 to 6 VDC | 390 Ω±20% | 4 VDC max. | 1 VDC min. |
12 VDC | 9.6 to 14.4 VDC | 900 Ω±20% | 9.6 VDC max. | ||
24 VDC | 19.2 to 28.8 VDC | 2 kΩ±20% | 19.2 VDC max. | ||
G3HD-X03SN-VD | 5 to 24 VDC | 4 to 28 VDC | 1.5 kΩ +20%/-10% (See note 1.) | 4 VDC max. | 1 VDC min. |
G3H-203S-VD | 4 to 24 VDC | 3 to 28 VDC | 15 mA max. (See note 2.) | 3 VDC max. | 1 VDC min. |
G3H-203SL-VD | 5 VDC | 4 to 6 VDC | 390 Ω±20% | 4 VDC max. | 1 VDC min. |
12 VDC | 9.6 to 14.4 VDC | 900 Ω±20% | 9.6 VDC max. | ||
24 VDC | 19.2 to 28.8 VDC | 2 kΩ±20% | 19.2 VDC max. | ||
G3HD-X03S-VD | 4 to 24 VDC | 3 to 28 VDC | 1.5 kΩ +20%/-10% (See note 1.) | 3 VDC max. | 1 VDC min. |
G3HD-202SN-VD | 12 to 24 VDC | 9.6 to 28.8 VDC | 25 mA max. (at 24 VDC) (See note 2.) | 9.6 VDC max. | 1 VDC min. |
Note: 1. The input impedance is given for the maximum operating voltage. For details, refer to the Technical Guide for
Solid State Relays.
2. With constant current input system.
Model | Applicable load | |||
---|---|---|---|---|
Rated load voltage | Load voltage range | Load current | Inrush current | |
G3H-203SN-VD G3H-203S-VD | 100 to 240 VAC | 75 to 264 VAC | 0.1 to 3 A at 40°C | 45 A 60 Hz, 1 cycle |
G3H-203SLN-VD G3H-203SL-VD | ||||
G3HD-X03SN-VD G3HD-X03S-VD | 4 to 48 VDC | 3 to 52.8 VDC | 0.1 to 3 A at 40°C | 18 A (10 ms) |
G3HD-202SN-VD | 24 to 240 VDC | 19.2 to 264 VDC | 0.001 to 2.5 A at 40°C | 20 A (10 ms) |
Model | G3H-203SN-VD/ 203S-VD | G3H-203SLN-VD/ 203SL-VD | G3HD-X03SN-VD/ X03S-VD | G3HD-202SN-VD |
---|---|---|---|---|
Operate time | 1/2 cycle of load power source + 1 ms max. | 1 ms max. | 0.5 ms max. | 5 ms max. |
Release time | 1/2 cycle of load power source + 1 ms max. | 2 ms max. | 10 ms max. | |
Output ON voltage drop | 1.6 V (RMS) max. | 3 V max. (output ON- resistance: 1.25 Ω max.) | ||
Leakage current | 5 mA max. (at 100 VAC); 10 mA max. (at 200 VAC) | 2.5 mA max. (at 100 VAC); 5 mA max. (at 200 VAC) | 5 mA max. (at 50 VDC) | 0.1 mA max. (at 200 VDC) |
Insulation resistance | 100 MΩ min. (at 500 VDC) | |||
Dielectric strength | 2,000 VAC, 50/60 Hz for 1 min | 1,500 VAC, 50/60 Hz for 1 min | ||
Vibration resistance | Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude | |||
Shock resistance | Destruction: 1,000 m/s2 | |||
Ambient temperature | Operating: -30°C to 80°C (with no icing) Storage: -30°C to 100°C (with no icing) | |||
Ambient humidity | 45% to 85% | |||
Certified standards | G3H: UL508, CSA C22.2 No. 14, EN60947-4-3 G3HD: UL508, CSA C22.2 No. 14, EN60950-1 | |||
EMC | Emission: EN55011 Group 1 Class B Immunity: EN61000-6-2 | |||
Weight | Approx. 50 g |
last update: November 06, 2012