If you have just landed here, this product OMRON G3PH Relays,Relays is offered online by Tianin FLD Technical Co.,Ltd. This is an online store providing Relays at wholesale prices for consumers. You can call us or send enquiry, we would give you the prices, packing,deliverty and more detailed information on the G3PH We cooperate with DHL,TNT,FEDEX,UPS,EMS,etc.They guarantee to meet your needs in terms of time and money,even if you need your OMRON G3PHRelays tomorrow morning (aka overnight or next day air) on your desk, 2, 3 days or more.Note to international customers, YES, we ship worldwide.
X General-purpose Basic Switch/Features
D4A-[]N General-purpose Limit Switch/Features
F3SR-B Safety Light Curtain/Features
GT1-ROS16 / ROP08 / FOP08 Relay Output Units/Features
XS5 Round Water-resistant Connectors (M12 Smartclick)/Features
last update: November 06, 2012
| Insulation method | Operation indicator | Zero cross function | Applicable output load * | Rated input voltage | Model |
|---|---|---|---|---|---|
| Photocoupler | Yes (yellow) | Yes | 75 A, 100 to 240 VAC | 5 to 24 VDC | G3PH-2075B DC5-24 |
| 100 to 240 VAC | G3PH-2075B AC100-240 | ||||
| 150 A, 100 to 240 VAC | 5 to 24 VDC | G3PH-2150B DC5-24 | |||
| 100 to 240 VAC | G3PH-2150B AC100-240 | ||||
| No | 75 A, 100 to 240 VAC | 5 to 24 VDC | G3PH-2075BL DC5-24 | ||
| 150 A, 100 to 240 VAC | 5 to 24 VDC | G3PH-2150BL DC5-24 | |||
| Yes | 75 A, 180 to 480 VAC | 5 to 24 VDC | G3PH-5075B DC5-24 | ||
| 100 to 240 VAC | G3PH-5075B AC100-240 | ||||
| 150 A, 180 to 480 VAC | 5 to 24 VDC | G3PH-5150B DC5-24 | |||
| 100 to 240 VAC | G3PH-5150B AC100-240 | ||||
| No | 75 A, 180 to 480 VAC | 5 to 24 VDC | G3PH-5075BL DC5-24 | ||
| 150 A, 180 to 480 VAC | 5 to 24 VDC | G3PH-5150BL DC5-24 |
Note:The Thyristor Module is built in.
* The applicable output load depends on the ambient temperature. For details, refer to Load Current vs. Ambient
Temperature in Engineering Data on Catalog.
| Name | Applicable output load * | Applicable models | Model |
|---|---|---|---|
| Thyristor Module | 75 A, 75 to 264 VAC | G3PH-2075B(L) | G32A-P2075 |
| 150 A, 75 to 264 VAC | G3PH-2150B(L) | G32A-P2150 | |
| 75 A, 150 to 528 VAC | G3PH-5075B(L) | G32A-P5075 | |
| 150 A, 150 to 528 VAC | G3PH-5150B(L) | G32A-P5150 |
* The applicable output load depends on the ambient temperature. For details, refer to Load Current vs. Ambient
Temperature in Engineering Data on Catalog.
last update: November 06, 2012
| Catalog Name | Catalog Number [size] | Last Update | |
|---|---|---|---|
| | J177-E1-01 [1076KB] | Aug 29, 201220120829 | G3PH Data Sheet |
last update: November 06, 2012
last update: November 06, 2012
last update: November 06, 2012
| Rated voltage | Operating voltage | Impedance (input current) | Voltage level | |
|---|---|---|---|---|
| Must operate voltage | Must release voltage | |||
| 5 to 24 VDC | 4 to 30 VDC | (5 mA max.) * | 4 VDC max. | 1.0 VDC min. |
| 100 to 240 VAC | 75 to 264 VAC | 41 kΩ ±20% | 75 VAC max. | 20 VAC min. |
* A constant-current circuit is used for the input current to the G3PH.
| Model | Applicable load | |||
|---|---|---|---|---|
| Rated load voltage | Load voltage range | Load current * | Inrush current resistance | |
| G3PH-2075B(L) | 100 to 240 VAC | 75 to 264 VAC | 1 to 75 A (at 40°C) | 800 A (60 Hz, 1 cycle) |
| G3PH-2150B(L) | 100 to 240 VAC | 75 to 264 VAC | 1 to 150 A (at 40°C) | 1,800 A (60 Hz, 1 cycle) |
| G3PH-5075B(L) | 180 to 480 VAC | 150 to 528 VAC | 1 to 75 A (at 40°C) | 800 A (60 Hz, 1 cycle) |
| G3PH-5150B(L) | 180 to 480 VAC | 150 to 528 VAC | 1 to 150 A (at 40°C) | 1,800 A (60 Hz, 1 cycle) |
* The load current depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in
Engineering Data on Catalog.
| Model | G3PH- 2075B | G3PH- 2150B | G3PH- 5075B | G3PH- 5150B | G3PH- 2075BL | G3PH- 2150BL | G3PH- 5075BL | G3PH- 5150BL |
|---|---|---|---|---|---|---|---|---|
| Operate time | 1/2 of load power source cycle + 1 ms max. for DC input 3/2 of load power source cycle + 1 ms max. for AC input | 1 ms max. | ||||||
| Release time | 1/2 of load power source cycle + 1 ms max. for DC input 3/2 of load power source cycle + 1 ms max. for AC input | 1/2 of load power source cycle + 1 ms max. | ||||||
| Output ON voltage drop | 1.6 V (RMS) max. | |||||||
| Leakage current | 30 mA max. (at 240 VAC) | 60 mA max. (at 480 VAC) | 30 mA max. (at 240 VAC) | 60 mA max. (at 480 VAC) | ||||
| Insulation resistance | 100 MΩ min. (at 500 VDC) | |||||||
| Dielectric strength | 2,500 VAC, 50/60 Hz for 1 min | |||||||
| Vibration resistance | 10 to 55 to10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude) Acceleration of 50 m/s2 for 50 min in X, Y and Z directions (10 sweeps of 5 min each = 50 min total) | |||||||
| Shock resistance | 500 m/s2, 3 times in X, Y, and Z directions | |||||||
| Ambient storage temperature | -30 to 100°C (with no icing or condensation) | |||||||
| Ambient operating temperature | -30 to 80°C (with no icing or condensation) | |||||||
| Ambient operating humidity | 45% to 85% | |||||||
| Weight | Approx. 1.8 kg | Approx. 3.0 kg | Approx. 1.8 kg | Approx. 3.0 kg | Approx. 1.8 kg | Approx. 3.0 kg | Approx. 1.8 kg | Approx. 3.0 kg |
last update: November 06, 2012