OMRON E3X-HD Smart Fiber Sensor/Features Fiber Sensors--OMRON E3X-HD Online Store

OMRON E3X-HDSensors/ Fiber Sensors/Fiber Amplifier

OMRON E3X-HD Sensors

OMRON E3X-HD Dimensions

/Images/l_3103-25-118742-198x198.jpg

Stable

No Maintenance

[Smart Power Control] Long-term stable detection with no maintenance

button once with a workpiece and once without a workpiece to automatically set the optimum incident level and threshold regardless of the workpiece.
The optimum settings can be performed regardless of skills and languages.
The setting dispersion of the Sensors is also eliminated to enable smoothly shifting from trial production to mass production, which contributes to the reduction of introduction cost.

E3X-HD Features 11 E3X-HD Features 12 E3X-HD Features 13

Point

Smart Tuning evolved from the popular power tuning feature of conventional Amplifiers, and yet is easier to use.
It enables easily reproducing stable detection conditions by newcomers or by operators on a site of the factory overseas. The incident level is displayed without modification (0 to 9,999) to make it easier to understand and to provide operators with a sense of ease with the larger numbers.

Let the E3X-HD Help You Save Energy

[Smart Eco Drive] Contribute to energy saving of equipment

The increased power efficiency of the newly developed GIGA RAY II and the new circuit design reduce power consumption by 25% over conventional models. This supports saving energy and power in your equipment. Power consumption of only 720 mW has been realized in operation in Normal Mode. And there are no restrictions to sensing distance and response time.

E3X-HD Features 16

Point

You can use more Sensors with the same power supply capacity as before.

Purchase the OMRON Fiber Amplifier Please fill in the following

Title:

Email:

Tel:

Content:

Verification code:

If you have just landed here, this product OMRON E3X-HD Sensors,Sensors is offered online by Tianin FLD Technical Co.,Ltd. This is an online store providing Sensors at wholesale prices for consumers. You can call us or send enquiry, we would give you the prices, packing,deliverty and more detailed information on the E3X-HD We cooperate with DHL,TNT,FEDEX,UPS,EMS,etc.They guarantee to meet your needs in terms of time and money,even if you need your OMRON E3X-HDSensors tomorrow morning (aka overnight or next day air) on your desk, 2, 3 days or more.Note to international customers, YES, we ship worldwide.

E3X-DRT21 / SRT21 / CIF11 Communications Units for E3X-DA-N-series Fiber Amplifiers/Features
EE-SX47 / SX67 Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated)*1/Fe...
G3J-S Soft-start Solid State Contactors/Features
E52 (Exclusive Models) Temperature Sensor (Exclusive Models)/Features
XS5 NEXT Series Round Oil-resistant Connectors (M12 Smartclick)/Features


OMRON E3X-HD specification

E3X-HD Smart Fiber Sensor/Specifications

Ratings and Specifications

TypeStandardModel for
Sensor Communications
Unit *1
NPN outputE3X-HD11E3X-HD6E3X-HD14E3X-HD0
PNP outputE3X-HD41E3X-HD8E3X-HD44
Connecting methodPre-wiredWire-saving
Connector
*2
M8
connector
Communications
Unit connector
Light source (wavelength)Red, 4-element LED (625 nm)
Power supply voltage12 to 24 VDC ±10%, ripple (P-P) 10% max.Supplied from the connector
through the Sensor
Communications Unit
Power
consump
tion
Normal mode720 mW max.
(Current consumption: 30 mA max. at 24 VDC, 60 mA max. at 12 VDC)
Eco ON530 mW max.
(Current consumption: 22 mA max. at 24 VDC, 44 mA max. at 12 VDC)
Eco LO640 mW max. (Current consumption: 26 mA max. at
24 VDC, 53 mA max.at 12 VDC)
-
Control outputLoad power supply voltage: 26.4 VDC max., open-
collector output
Load current:
Groups of 1 to 3 Amplifier Units: 100mA max.,
Groups of 4 to 16 Amplifier Units: 20mA max.
Residual voltage:
At load current of less than 10 mA: 1 V max.,
At load current of 10 to 100 mA: 2 V max.
OFF current: 0.1 mA max.
-
Protection circuitsPower supply reverse polarity protection, output
short-circuit protection and output reverse
polarity protection
Power supply reverse polarity
protection and output short-
circuit protection
Response
time
Super-high-speed
mode (SHS) *3
NPN outputs: Operate or reset: 50 μs
PNP outputs: Operate or reset: 55 μs
-
High-speed Mode
(HS)
Operate or reset: 250 μs (default setting)
Standard Mode
(STND)
Operate or reset: 1 ms
Giga-power Mode
(GIGA)
Operate or reset: 16 ms
Maximum connectable Units16 unitswith E3X-CRT: 16 units
with E3X-ECT: 30 units
Mutual interference
prevention
Possible for up to 10 units (optical communications sync) *3
Auto power control (APC)Always ON
Other functionsPower tuning, differential detection, DPC, timer (OFF-delay, ON-delay, or one-shot),
zero reset, resetting settings, and Eco mode
Ambient illumination
(Receiver side)
Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max.
Ambient temperature rangeOOperating:
Groups of 1 to 2 Amplifiers: -25 to 55°C,
Groups of 3 to 10 Amplifiers: -25 to 50°C,
Groups of 11 to 16 Amplifiers: -25 to 45°C
Storage: -30 to 70°C
(with no icing or condensation)
Operating:
Groups of 1 to 2 Amplifiers:
0 to 55°C,
Groups of 3 to 10 Amplifiers:
0 to 50°C,
Groups of 11 to 16 Amplifiers:
0 to 45°C,
Groups of 17 to 30 Amplifiers:
0 to 40°C
Storage: -30 to 70°C
(with no icing or condensation)
Ambient humidity rangeOperating and storage: 35% to 85% (with no condensation)
Insulation resistance20 MΩ min. (at 500 VDC)
Dielectric strength1,000 VAC at 50/60 Hz for 1 minute
Vibration resistance
(destruction)
10 to 55 Hz with a 1.5-mm double amplitude for
2 hours each in X, Y, and Z directions
10 to 150 Hz with a 0.7-mm
double amplitude for 80 minutes
each in X, Y, and Z directions
Shock resistance
(destruction)
500 m/s2 for 3 times each in X, Y, and Z
directions
150 m/s2 for 3 times each in
X, Y, and Z directions
Degree of protectionIEC 60529 IP50
(with Protective Cover attached)
-
Weight
(packed state/unit only)
Approx. 105 g/
Approx. 65 g
Approx. 60 g/
Approx. 20 g
Approx. 70 g/
Approx. 25 g
Approx. 65 g/Approx. 25 g
MaterialsCasePolycarbonate (PC)Heat-resistant ABS
(connector: PBT)
CoverPolycarbonate (PC)
CablePVC-
AccessoriesInstruction Manual

*1. The E3X-ECT EtherCAT Sensor Communications Unit and the E3X-CRT CompoNet Sensor Communications Unit can be used.
*2. Use either the E3X-CN11 (master connector, 3 conductors) or the E3X-CN12 (slave connector, 1 conductor).
*3. The communications function and mutual interference prevention function are disabled when the detection mode is set to Super-high-speed mode (SHS).
When including E3X-DA-S with activated power tuning, mutual interference prevention is possible for up to 6 units.
When including E3X-MDA with activated power tuning, mutual interference prevention is possible for up to 5 units.

Sensing Distances

Threaded Models

Sensing
method
Sensing
direction
SizeModelSensing distance (mm)
Giga modeStandard modeHigh-speed
mode
Super-high-
speed mode
Through-beamRight-angleM4E32-T11N 2M2,0001,000700280
E32-LT11N 2M4,000 *3,5002,300920
StraightE32-T11R 2M2,0001,000700280
E32-LT11 2M4,000 *4,000 *2,7001,080
E32-LT11R 2M4,000 *3,5002,300920
ReflectiveRight-angleM3E32-C31N 2M110504614
E32-C21N 2M2901309039
M4E32-D21N 2M840350240100
M6E32-C11N 2M780350320100
E32-LD11N 2M840350240100
StraightM3E32-D21R 2M140604016
E32-C31 2M33015010044
E32-C31M 1M
M4E32-D211R 2M140604016
M6E32-D11R 2M840350240100
E32-CC200 2M1,400600400180
E32-LD11 2M860360250110
E32-LD11R 2M840350240100

* The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.

Cylindrical Models

Sensing
method
SizeSensing
direction
ModelSensing distance (mm)
Giga modeStandard
mode
High-speed
mode
Super-high-
speed mode
Through-
beam
1 dia.Top-viewE32-T223R 2M45025015060
1.5 dia.E32-T22B 2M68040022090
3 dia.E32-T12R 2M2,0001,000700280
Side-viewE32-T14LR 2M750450260100
Reflective1.5 dia.Top-viewE32-D22B 2M140604016
1.5 dia. + 0.5 dia.E32-D43M 1M281284
3 dia.E32-D22R 2M140604016
E32-D221B 2M3001409040
E32-D32L 2M70030020090
3 dia. + 0.8 dia.E32-D33 2M7030208

Flat Models

Sensing
method
Sensing directionModelSensing distance (mm)
Giga modeStandard
mode
High-speed
mode
Super-high-
speed mode
Through-beamTop-viewE32-T15XR 2M2,0001,000700280
Side-viewE32-T15YR 2M750450260100
Flat-viewE32-T15ZR 2M
ReflectiveTop-viewE32-D15XR 2M840350240100
Side-viewE32-D15YR 2M2001005224
Flat-viewE32-D15ZR 2M

Sleeve Models

Sensing
method
Sensing directionModelSensing distance (mm)
Giga modeStandard
mode
High-speed
mode
Super-high-
speed mode
Through-beamSide-viewE32-T24R 2M1701005020
E32-T24E 2M45025015060
Top-viewE32-T33 1M150905020
E32-T21-S1 2M51030017068
E32-TC200BR 2M2,0001,000700280
ReflectiveSide-viewE32-D24R 2M7030208
E32-D24-S2 2M120534514
Top-viewE32-D43M 1M281284
E32-D331 2M14642
E32-D33 2M7030208
E32-D32-S1 0.5M6324187
E32-D31-S1 0.5M
E32-DC200F4R 2M140604016
E32-D22-S1 2M2501107230
E32-D21-S3 2M
E32-DC200BR 2M840350240100
E32-D25-S3 2M2501107230

Small-spot, Reflective Models

TypeSpot
diameter
Center
distance
(mm)
ModelsSensing distance (mm)
Giga
mode
Standard
mode
High-speed
mode
Super-high-
speed mode
Variable
spot
0.1 to 0.6 dia.6 to 15E32-C42 1M+E39-F3ASpot diameter of 0.1 to 0.6 mm at 6 to 15 mm.
0.3 to 1.6 dia.10 to 30E32-C42 1M+E39-F17Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm.
Parallel
light
4 dia.0 to 20E32-C31 2M+E39-F3CSpot diameter of 4 mm max. at 0 to 20 mm.
E32-C31N 2M+E39-F3C
Integrated
lens
0.1 dia.5E32-C42S 1MSpot diameter of 0.1 mm at 5 mm.
6 dia.50E32-L15 2MSpot diameter of 6 mm at 50 mm.
Small-
spot
0.1 dia.7E32-C41 1M+E39-F3A-5Spot diameter of 0.1 mm at 7 mm.
0.5 dia.E32-C31 2M+E39-F3A-5Spot diameter of 0.5 mm at 7 mm.
E32-C31N 2M+E39-F3A-5
0.2 dia.17E32-C41 1M+E39-F3BSpot diameter of 0.2 mm at 17 mm.
0.5 dia.E32-C31 2M+E39-F3BSpot diameter of 0.5 mm at 17 mm.
E32-C31N 2M+E39-F3B
3 dia.50E32-CC200 2M+E39-F18Spot diameter of 3 mm at 50 mm.
E32-C11N 2M+E39-F18

High-power Beam Models

TypeSensing
direction
Aperture
angle
ModelsSensing distance (mm)
Giga
mode
Standard
mode
High-
speed
mode
Super-
high-
speed
mode
Through-beam
models with
integrated
lens
Right-angle15°E32-LT11N 2M4,000 *23,5002,300920
Top-view10°E32-T17L 10M20,000 *120,000 *120,000 *18,000
15°E32-LT11 2M4,000 *24,000 *22,7001,080
E32-LT11R 2M4,000 *23,5002,300920
Side-view30°E32-T14 2M4,000 *24,000 *24,000 *21,800
Through-beam
models with
lenses
Right-angle12°E32-T11N 2M+E39-F14,000 *24,000 *24,000 *22,000
E32-T11N 2M+E39-F164,000 *24,000 *24,000 *23,600
Top-view12°E32-T11R 2M+E39-F14,000 *24,000 *24,000 *22,000
E32-T11R 2M+E39-F164,000 *24,000 *24,000 *23,600
Side-view60°E32-T11R 2M+E39-F21,450800500200
Top-view12°E32-T11 2M+E39-F14,000 *24,000 *24,000 *21,860
E32-T11 2M+E39-F164,000 *24,000 *24,000 *24,000 *2
Side-view60°E32-T11 2M+E39-F22,3001,320860320
Top-view12°E32-T51R 2M+E39-F14,000 *24,000 *23,9001,500
E32-T51R 2M+E39-F164,000 *24,000 *24,000 *24,000 *2
Side-view60°E32-T51R 2M+E39-F21,400720500200
Top-view12°E32-T81R-S 2M+E39-F14,000 *24,000 *22,7001,000
E32-T81R-S 2M+E39-F164,000 *24,000 *24,000 *21,800
Side-view60°E32-T81R-S 2M+E39-F21,000550360140
Top-view12°E32-T61-S 2M+E39-F14,000 *24,000 *24,000 *21,800
E32-T61-S 2M+E39-F164,000 *24,000 *24,000 *23,100
Side-view60°E32-T61-S 2M+E39-F21,680900600240
Top-view12°E32-T51 2M+E39-F1-334,000 *24,000 *22,3001,400
E32-T51 2M+E39-F164,000 *24,000 *24,000 *24,000 *2
Reflective
models with
integrated lens
Top-viewE32-D16 2M40 to
2,800
40 to
1,400
40 to 90040 to 480

*1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm.
*2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.

Narrow View Models

Sensing
method
Sensing
direction
Aperture
angle
ModelSensing distance (mm)
Giga modeStandard
mode
High-speed
mode
Super-high-
speed mode
Through-beamSide-view1.5°E32-A03 2M3,2201,7801,200500
E32-A03-1 2M
3.4°E32-A04 2M1,280680450200
E32-T24SR 2M4,000 *2,2001,460580
E32-T24S 2M4,000 *2,6001,740700
E32-T22S 2M4,000 *3,8002,5001,000

* The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.

Models for Detection without Background Interference

Sensing
method
Sensing
direction
ModelSensing distance (mm)
Giga modeStandard modeHigh-speed
mode
Super-high-speed
mode
Limited-
reflective
Flat-viewE32-L16-N 2M0 to 150 to 12
E32-L24S 2M0 to 4
Side-viewE32-L25L 2M5.4 to 9 (center 7.2)

Transparent Object Detection (Retro-reflective Models)

Sensing
method
FeatureSizeModelsSensing distance (mm)
Giga modeStandard
mode
High-speed
mode
Super-high-
speed mode
Retro-
reflective
Film detectionM3E32-C31 2M
+E39-F3R
+E39-RP37
250200---
Square---E32-R16 5M150 to 1,500
ThreadedM6E32-R21 2M10 to 250
Hex-shapedE32-LR11NP 2M
+E39-RP1
1,3501,2001,000550

Transparent Object Detection (Limited-reflective Models)

Sensing
method
FeatureSensing
direction
ModelSensing distance (mm)
Giga
mode
Standard
mode
High-speed
mode
Super-high-
speed mode
Limited-
reflective
Small sizeFlat-viewE32-L24S 2M0 to 4
StandardE32-L16-N 2M0 to 150 to 12
Glass substrate
alignment, 70°C
E32-A08 2M10 to 20---
Standard/long-distanceE32-A12 2M12 to 30---
Side-view formSide-viewE32-L25L 2M5.4 to 9 (center 7.2)
Glass substrate
mapping, 70°C
Top-viewE32-A09 2M15 to 38---

Chemical-resistant, Oil-resistant Models

Sensing
method
TypeSensing
direction
ModelSensing distance (mm)
Giga modeStandard
mode
High-speed
mode
Super-high-
speed mode
Through-
beam
Oil-resistantRight-angleE32-T11NF 2M4,000 *14,000 *14,000 *12,200
Chemical/
oil-resistant
Top-viewE32-T12F 2M4,000 *14,000 *14,000 *11,600
E32-T11F 2M4,000 *14,000 *12,6001,000
Side-viewE32-T14F 2M1,400800500200
Chemical/
oil-resistant at
150°C
Top-viewE32-T51F 2M4,000 *12,8001,800700
ReflectiveSemiconductors:
Cleaning,
developing, and
etching; 60°C
Top-viewE32-L11FP 5M8 to 20 mm from tip of lens (Recommended sensing
distance: 11 mm),
19 to 31 mm from center of mounting hole A
(Recommended sensing distance: 22 mm)
Semiconductors:
Resist stripping;
85°C
E32-L11FS 5M8 to 20 mm from tip of lens (Recommended sensing
distance: 11 mm),
32 to 44 mm from center of mounting hole A
(Recommended sensing distance: 35 mm)
Chemical/
oil-resistant
E32-D12F 2M--- *219013060
Chemical-
resistant cable
E32-D11U 2M840350240100

*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
*2. Even if there is no sensing object, the Sensor will detect light that is reflected by the fluororesin.

Bending-resistant Models

Sensing
method
SizeModelSensing distance (mm)
Giga modeStandard modeHigh-speed
mode
Super-high-speed
mode
Through-beam1.5 dia.E32-T22B 2M68040022090
M3E32-T21 2M
M4E32-T11 2M2,5001,350900360
SquareE32-T25XB 2M50030017070
Reflective1.5 dia.E32-D22B 2M140604016
M3E32-D21 2M
3 dia.E32-D221B 2M3001409040
M4E32-D21B 2M
M6E32-D11 2M840350240100
SquareE32-D25XB 2M2401006030

Heat-resistant Models

Sensing
method
SizeModelSensing distance (mm)
Giga modeStandard modeHigh-speed
mode
Super-high-
speed mode
Through-beam100°CE32-T51R 2M1,600800560225
150°CE32-T51 2M2,8001,5001,000400
200°CE32-T81R-S 2M1,000550360140
350°CE32-T61-S 2M1,680900600240
Reflective100°CE32-D51R 2M67028019080
150°CE32-D51 2M1,120450320144
200°CE32-D81R-S 2M42018012054
300°CE32-A08H2 2M10 to 20---
E32-A09H2 2M20 to 30 (center 25)---
350°CE32-D611-S 2M42018012054
E32-D61-S 2M
400°CE32-D73-S 2M2801208036

Area Detection Models

Sensing
method
TypeSensing widthModelSensing distance (mm)
Giga modeStandard
mode
High-speed
mode
Super-high-
speed mode
Through-beamArea11 mmE32-T16PR 2M3,1001,7001,120440
E32-T16JR 2M2,7501,500960380
30 mmE32-T16WR 2M4,0002,6001,700680
ReflectiveArray11 mmE32-D36P1 2M70030020090

* The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.

Liquid-level Detection Models

Sensing
method
Tube
diameter
FeatureModelSensing distance (mm)
Giga modeStandard
mode
High-speed
mode
Super-high-
speed mode
Tube-
mounting
3.2, 6.4, or
9.5 dia
Stable
residual
quantity
detection
E32-A01 5MApplicable tube: Transparent tube with a diameter of 3.2,
6.4, or 9.5 mm, Recommended wall thickness: 1 mm
8 to 10 diaMounting at
multiple
levels
E32-L25T 2MApplicable tube: Transparent tube with a diameter of 8
to 10 mm, Recommended wall thickness: 1 mm
No
restrictions
Large tubesE32-D36T 5MApplicable tube: Transparent tube
(no restrictions on diameter)
Liquid contact
(heat-resistant
up to 200°C)
------E32-D82F1 4MLiquid-contact type

Vacuum-resistant Models

Sensing
method
Heat-resistant
temperature
ModelSensing distance (mm)
Giga modeStandard
mode
High-speed
mode
Super-high-
speed mode
Through-beam120 °CE32-T51V 1M720400260100
E32-T51V 1M+E39-F1V2,000 *2,000 *1,360520
200 °CE32-T84SV 1M1,760950640260

* The fiber length is 1 m on each side, so the sensing distance is given as 2,000 mm.

Models for FPD, Semiconductors, and Solar Cells

Sensing
method
ApplicationOperating
temperature
ModelSensing distance (mm)
Giga modeStandard
mode
High-speed
mode
Super-high-
speed mode
Limited-
reflective
Glass presence
detection
70°CE32-L16-N 2M0 to 150 to 12
E32-A08 2M10 to 20---
Glass substrate
alignment
300°CE32-A08H2 3M
70°CE32-A12 2M12 to 30---
Glass substrate
mapping
E32-A09 2M15 to 38---
300°CE32-A09H2 2M20 to 30 (center 25)---
Wet processes:
Cleaning, Resist
developing and
etching
60°CE32-L11FP 5M8 to 20 mm from tip of lens
(Recommended sensing distance: 11 mm),
19 to 31 mm from center of mounting hole A
(Recommended sensing distance: 22 mm)
Wet process:
Resist stripping
85°CE32-L11FS 5M8 to 20 mm from tip of lens
(Recommended sensing distance: 11 mm),
32 to 44 mm from center of mounting hole A
(Recommended sensing distance: 35 mm)
Through-
beam
Wafer mapping70°CE32-A03 2M3,2201,7801,200500
E32-A03-1 2M
E32-A04 2M1,280680450200
E32-T24SR 2M4,000 *2,2001,460580
E32-T24S 2M4,000 *2,6001,740700

* The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.


OMRON E3X-HD lineup

E3X-HD Smart Fiber Sensor/Lineup

E3X-HD Series

Amplifier Units

TypeAppearanceConnection methodModel
NPN outputPNP output
Standard models3103_lu_1_1Pre-wired (2 m)E3X-HD11 2ME3X-HD41 2M
3103_lu_1_2Wire-saving connectorE3X-HD6E3X-HD8
3103_lu_1_3M8 connectorE3X-HD14E3X-HD44
For Communications Unit connection3103_lu_1_4Communications UnitE3X-HD0

Wire-saving Connectors (Order Separately)

(An Amplipier Unit with a wire-saving connector is required.)
Connectors are not provided with the Amplifier Units.
TypeAppearanceCable lengthNumber of conductorsModel
Master connector3103_lu_2_12 m3E3X-CN11
Slave connector3103_lu_2_21E3X-CN12

E3X-HD Lineup 4

There is no master/slave distinction for the Amplifiers.Along with the Amplifier, purchase the Connectors that are required for applications.

Sensor I/O Connectors (Order Separately)

(An Amplipier Unit with a M8 connector is required.) Connectors are not provided with the Amplifier Units.
AppearanceCable lengthNumber of conductorsModel
Straight3103_lu_4_12 m4XS3F-M421-402-A
Right-angle3103_lu_4_2XS3F-M422-402-A

Communications Units

Communications methodAppearanceApplicable Fiber Amplifier UnitsModel
CompoNet3103_lu_5_1E3X-HD0
E3X-MDA0
E3X-DA0-S
E3X-CRT
EtherCAT3103_lu_5_2E3X-ECT


OMRON E3X-HD dimension

E3X-HD Smart Fiber Sensor/Dimensions

If you have a question about this product, please click on "Inquiry" above.
Or contact your nearest OMRON through "Products Links" in the top right corner.


OMRON E3X-HD catalog

E3X-HD Smart Fiber Sensor/Catalog

  • Catalog
  • Manual
  • CAD

English

Global Edition

For ordering in Singapore, please note some product models not sold in Singapore may be included in the following catalog(s) for our global customers.

*It is recommended to select “Save” from the right-click due to large size of catalog PDF data.

Catalog Name Catalog Number
[size]
Last Update
E3X-HD Data Sheet -
[3892KB]
Jul 01, 201620160701 E3X-HD Data Sheet
E3X-HD Catalog E417-E1-01
[2333KB]
Sep 01, 201620160901 E3X-HD Catalog


Return to OMRON